PlaceDossier / Zoning / City of Cranbrook

R-3: Cluster Development

R-3 is a zone in City of Cranbrook Zoning Bylaw No. 3977, 2019 (City of Cranbrook). Our summary of Part 7.08 of the bylaw as amended to September 8, 2026.

What the zone allows

Homes allowed
Up to 4 homes on a lot over 280 m², 3 on a smaller one, in one main building: a house, duplex, triplex or fourplex, with at most one secondary suite per main home (ss. 7.08.1, 7.08.2, 7.08.4). In a cluster development, several buildings on one site at up to 30 homes per gross hectare (s. 7.08.4(d)). Whether a secondary suite counts toward the 3 or 4 is unclear, so ask the City
Main uses
A house, duplex, triplex or fourplex, or a cluster development; a home-based business, a secondary suite, other accessory uses (ss. 7.08.1, 7.08.2)
Smallest lot for a subdivision
1.0 ha, at least 12.0 m along the street (9.0 m on a cul-de-sac bulb) (s. 7.08.3)
Lot coverage
40%, except in a cluster development, where the zone sets none (s. 7.08.6(d))
Height limit
House 7.6 m; duplex, triplex or fourplex 8.6 m or 2½ storeys, whichever is less; accessory buildings 4.5 m (s. 7.08.6(b), (c))
Setbacks
Main building: front 6.0 m, rear 6.0 m, sides 2.1 m (never under 1.5 m on an irregular lot), street side 4.5 m; a house outside a cluster development may sit on one side line if the other side is 2.7 m and the neighbour's lot carries a 1.5 m maintenance easement. Accessory buildings: front 6.0 m, rear 2.1 m (0.9 m with no lane), sides 0.9 m (one 2.7 m on an inside lot with no lane), street side 4.5 m, 1.0 m from the main building. In a bare land strata, setbacks are measured from the parent lot's lines (s. 7.08.5)

One main use per lot, unless the lot is a cluster development (s. 7.08.4(c)).

A cluster development is houses, duplexes, triplexes or fourplexes on their own lots, or ground-oriented multi-family housing, laid out to one design with a large shared amenity area, considered where a site has trees, watercourses, ravines, heritage or slopes worth keeping; every one needs a development permit (Part 3), and at least 10% of it is recreational space (s. 7.08.6(f)).

Each home at least 65.0 m² of floor area; a house at least 7.3 m across (s. 7.08.6(a), (e)).

A secondary suite has its own entrance, outside or off a shared indoor landing (an inside door to the main home is allowed), is built to the BC Building Code with a building permit, and has one parking space on the lot; at most one per main home (s. 4.17.1). One per main home (s. 7.08.4(e)). The zone doesn't list a detached accessory dwelling.

No wrecking or repairing vehicles on the lot, and at most one derelict vehicle, kept out of the front yard (s. 7.08.7).

A home-based business is run only by family members living in the home, with no help on the premises from anyone else (with the Licence Inspector's written leave, a stand-in may run it while the licence holder is away up to 6 months at a time and 12 months in two years); it's carried on inside the home or a permitted accessory building, makes no offensive noise, traffic, smoke, dust, odour or glare, shows nothing outside but one unlit name plate of up to 0.2 m² on the building, needs no regular deliveries by commercial vehicle, parks in the front yard only on a driveway or built parking area, and sells only goods made on the premises (s. 4.06). It may be a bed and breakfast in a house (up to four guest rooms, no guest over 30 days in 12 months, one parking space a room), a residential office with no client visits, or a day care, never auto body or car repair (ss. 3.04, 6.12.4(b)).

An accessory building goes up only with or after the main building (farm buildings aside), is part of the main building where attached, and never sits on or over an easement (s. 4.07.1-.5).

Industrial uses and free span metal buildings aren't allowed (s. 4.04.2); shipping containers can't serve as storage buildings (s. 4.07.7); accessory buildings stay out of the front yard (s. 4.07.4), so the zone's front setback for them most likely never comes into play (our reading).

Fences at most 1.0 m high in the front yard and 1.8 m elsewhere, no barbed wire, and fences aren't held to the zone's setbacks (ss. 4.08.4, 4.11.1(a), 4.11.2); on a corner lot, nothing over 1.0 m high within the triangle 6.0 m along each lot line from the corner (s. 4.09).

Parking on the lot (s. 6.02.1): two spaces per home, one more for a secondary suite or accessory dwelling (s. 6.12.4); three or more spaces are paved, marked and drained on the lot (s. 6.06.2); no driveway onto an arterial street the Official Community Plan names unless it's the only access (s. 6.06.4).

Boxouts and cantilevers up to 0.6 m may reach into the setbacks (each at most 2.7 m long, together a third of the wall, clear of parking and driveways, and 3.0 m above the ground in a side yard used to drive to the rear), and steps, eaves and sun shades up to 1.2 m; patios, landscape features, underground structures, antennas and flag poles may too (s. 4.08.2). Height limits don't count chimneys, spires, towers, antennas, flag poles, elevator shafts, ventilators and solar collectors (s. 4.10.2); up to three storeys, a home, shop or industrial building's height runs from the average finished grade to halfway between the eaves and the top of the roof (s. 3.03.8).

An uncovered pool in a side or rear yard, fenced with a safety gate, may sit in the required yards but at least 3.0 m from the side and rear lines (s. 4.08.2(f)); a deck may reach 0.6 m into the rear yard on posts outside it, never into the front or side yards (s. 4.08.2(j)).

Solar panels on a roof, no higher than the building or past the roof edge (s. 4.19.3(a)); one wind turbine of up to 10 kW on a lot of 0.2 ha or more, 10.5 m high at most and 125% of its height from a neighbour's home (s. 4.19.5(a)); geothermal loops 3.0 m from lot lines and City easements (s. 4.19.4).

Allowed in every zone: public utility uses, parks, highways, mailboxes, street furniture, historical and archaeological display sites, conservation areas and reserves, and a building used as a polling station or campaign office (s. 4.03); intensive agriculture only on Agricultural Land Reserve land, where the Agricultural Land Commission Act also applies (ss. 4.04.1, 4.12). A lot smaller than the zone's minimum that existed when the bylaw took effect may still be used for the zone's uses (s. 4.02); a building or its services crossing a lot line need the lots consolidated or a covenant keeping them together (s. 5.03); a lot under 2.0 ha is connected to City sewer (s. 5.01.4); a lot in two zones counts each part as its own lot for size, coverage and density (s. 3.03.3).

Short-term rental of a home isn't a use the zone lists (a bed and breakfast is a kind of home-based business, s. 3.04), so ask the City before renting one by the night.

No building within 15.0 m of a watercourse at least 0.6 m deep that flows six months a year or drains 2.0 km² or more, unless the Floodplain Management Bylaw says otherwise; where a geotechnical no-development line is registered within a lot, setbacks are measured from it, not the lot line, except in subdivisions approved before 2009 (ss. 4.13.3(h), 4.14). Building in riparian land, a wetland or on steep or unstable slopes needs a development permit and, on slopes, an engineer's geotechnical assessment; a pool over 1,000 L stays 15.0 m from the top or toe of a slope, and no pool or hot tub drains over one (s. 4.13).

Site-specific exceptions listed in the bylaw by legal description can add or change uses for one property, and development permit areas, the ALR and building rules apply on top. Confirm with the City of Cranbrook's planning department before you buy or build.

Source: Part 7.08 of City of Cranbrook Zoning Bylaw No. 3977, 2019 (summarised in our words, checked 2026-10-31); zone map: Open Government Licence – British Columbia (named by the City of Cranbrook).

City of Cranbrook Zoning Bylaw No. 3977, 2019 applies in Cranbrook.

R-3 in other BC bylaws: what R-3 allows in each of the 21 we've summarised.

Other Residential Transition Zone RT, Residential Zone R-1, Cluster Development Zone R-3, Low and Medium Density Multiple Family Residential Zones R-4 and R-5, Mobile Home and Residential Zone R-7, Community Commercial Zone C-1, Highway Commercial Zone C-2, Light Industrial Zone M-2, Public Institutional Zone P-1, Clean Industrial Zone M-1, Community Recreation Zone P-2 and Comprehensive Development Zones CD-1 (Wildstone) and CD-3 (Shadow Mountain) zones in this bylaw

R-1 Residential, R-7 Mobile Home and Residential, C-1 Community Commercial, C-2 Highway Commercial, M-2 Light Industrial, P-1 Public Institutional, M-1 Clean Industrial, P-2 Community Recreation, CD-1 Comprehensive Development 1 (Wildstone), CD-3 Comprehensive Development 3 (Shadow Mountain), RT Residential Transition, R-4 Low Density Multiple Family Residential, R-5 Medium Density Multiple Family Residential.