PlaceDossier / Zoning / District of Squamish
UH-1: University Housing 1
UH-1 is a zone in District of Squamish Zoning Bylaw No. 2200, 2011 (District of Squamish). Our summary of Section 21 of the bylaw as amended to September 17, 2026.
What the zone allows
- Homes allowed
- Houses and duplexes (only where Figure 21.12 maps them), townhouses and apartments in Area 1/1A; townhouses, apartments, triplexes and fourplexes in Areas 2 and 3, with student and faculty housing in Area 3 (s. 21.1). At most 960 homes across the zone: 453 in Area 1/1A, 83 in Area 2, 424 in Area 3; townhouses up to 17 and apartments up to 35 per 0.40 ha in Areas 1/1A and 2; caps of 25 homes and 1 home on two parcels the bylaw names (s. 21.2). The zone lists no secondary suite; s. 4.38(a) allows an accessory dwelling unit in any zone that allows a house or duplex, so one may be added to a house or duplex here (our reading: ask the District how it counts against the Area caps)
- Main uses
- Homes as above, parks, schools, a child care facility, neighbourhood commercial, home occupations, short-term rental (rules below), assembly (in Area 1/1A only as an accessory use); in Area 3 also the university, a brewery, distillery or winery and a liquor primary establishment; accessory uses (s. 21.1)
- Smallest lot for a subdivision
- House 371.6 m², 13.7 m wide, 27.4 m deep; duplex 557.4 m², 20 m wide, 27.4 m deep; townhouses or apartments 4,047 m² (ss. 21.5, 21.6)
- Lot coverage
- 40%; 52% for houses and duplexes in Area 1 and for every use in Area 1A (s. 21.9)
- Height limit
- House or duplex 9 m; townhouse, triplex or fourplex 10.68 m; apartments 38.1 m; in Area 3, 10.68 m within 40 m of a lot line shared with a lot on Aristotle Drive or Aristotle Place (s. 21.8)
- Setbacks
- Houses and duplexes: in Area 1 front 7.62 m, rear 7.62 m, sides 2.13 m, street side 4.57 m; in Area 1A with a rear lane front 4.0 m (2.5 m to a covered porch), rear 5.0 m, sides 1.2 m, street side 2.4 m; in Area 1A without a lane front 6.0 m (4.5 m to a covered porch), rear 5.0 m, sides 1.8 m, street side 3.0 m. Townhouses and apartments in any Area, and other main buildings in Areas 1, 1A and 2: 7.62 m from every line; none for commercial buildings and apartments in the University Village Centre (s. 21.7). No setback is set for a triplex, fourplex or other building in Area 3, so that is unclear: ask the District. Also an accessory dwelling unit: the house's front and side setbacks and 1.5 m from the rear line (0.61 m on a lane) (s. 4.38(e)); accessory buildings and structures: not in the front yard, 1.2 m from interior side and rear lines (a greenhouse 1.0 m), and on a corner lot the main building's exterior side setback (s. 4.4(d)); a wildlife-proof enclosure on a lot with no lane is exempt from these (s. 4.4(e)); a garage or carport 0.61 m from a rear line on a lane (s. 4.4(d)(iii)); an uncovered swimming pool not in the front or exterior side yard and 3.0 m from interior side and rear lines (s. 4.11(i)); into a setback, bay windows, chimneys, fireplaces, sunshades and sills may reach 0.61 m, eaves and awnings 0.91 m, balconies 0.76 m, steps and landings 2.04 m, an open front porch or stairs up to 2 m high 3 m into the front setback, a solar device on a building 1.83 m, covered bicycle parking on a building 1.8 m, engineer-approved exterior cladding up to 0.165 m thick; patios up to 0.62 m high, accessible ramps, arbours, trellises, poles, antennas, signs and play areas are exempt (s. 4.11); on a corner lot nothing above 0.46 m in the 6.10 m sight triangle at the corner, up to the first storey, and nothing above 0.46 m where a driveway crosses a sidewalk (s. 4.8); no building or structure but signs within 4.57 m of the Highway 99 right of way (s. 4.20)
The zone is for a mix of housing and neighbourhood uses on the lands round Quest University that aren't campus, under the Official Community Plan's University Sub Area Plan (s. 21). The zone is split into Areas 1/1A, 2 and 3 on the bylaw's Figure 21.1; ask the District which Area a lot is in.
In Area 3, at least 30% of the homes are kept as rentals, one townhouse, triplex or fourplex is allowed for every 5 apartments built, and at most 340 apartments, 30 townhouses and 54 triplexes and fourplexes (ss. 21.2(i) to (k), 21.3, 21.4). One more named parcel keeps 30% of its homes as rentals (s. 21.3(b)).
Every triplex or fourplex has at least one home stacked above another (s. 21.13). In the University Village Centre, at least 2,090 m² of neighbourhood commercial or a liquor primary establishment comes before any other use (s. 21.11).
Short-term rental (stays under 90 days, bed and breakfasts included) is a listed use, but only in the operator's principal residence (where they live at least 183 days a year), with a District licence, and never in an accessory dwelling unit, accessory building, vehicle or tent (s. 4.46); one principal residence per person, and the whole home rented short term at most 182 days a year; parking under Section 41 and the building and fire bylaws' occupancy limits apply (ss. 4.46(e), (f); definitions in Section 1).
No home anywhere over 400 m² unless the bylaw sets another cap (s. 4.54). Accessory buildings: one of up to 60 m² a lot, plus up to five of 10 m² or less and 3 m high, not in the front yard, 4.58 m high (s. 4.4).
For apartments and townhouses, common useable open space of at least 30% of the lot for apartments and 40 m² a home for townhouses (the larger where a parcel has both), open space at grade at least 6.10 m across and no steeper than 5% (s. 4.29(a) to (c)). An apartment building of more than 20 homes has 2.0 m² of indoor amenity space a home, in one place (s. 4.43).
Parking (s. 21.10, Table 3): 2 spaces a house or duplex home; townhouses and apartments 1.25 a one-bedroom, 1.75 a two-bedroom and 2 a three-bedroom home (an apartment bachelor 1), plus 0.25 a home for visitors; student and faculty housing 1 space for every 3 units; at most 5 a house or duplex home and 3 a townhouse or apartment (Table 6).
The fence rule for Residential, Multiple Unit and Comprehensive zones (s. 4.6(a)) doesn't name University Housing zones, so whether its 1.83 m and 1.22 m limits apply here is unclear: ask the District. The landscaping rule of s. 4.27(a) doesn't name University Housing zones either, so whether it applies here is also unclear: Every part of the lot not used for buildings, outdoor display, parking or loading is landscaped and kept permeable; healthy trees and shrubs kept through construction unless the Building Inspector agrees they must go; new planting native or water-conserving, no invasive species (s. 4.27(a), (c), (d)).
Every zone also allows repairs, a site office while a building goes up, and, with a building permit, a covenant on title and security, living in an existing or temporary building while a new home is built (it is removed or converted once the home is done); water, sewer and drainage works, pipelines, power and telephone lines, streets and lanes, street lights and furniture, recycling bins, voting places and campaign offices for a time, interpretive signs, public art, parks, playgrounds, trails, urban agriculture, a neighbourhood energy utility, assisted living, community care facilities, transitional housing, emergency shelters and public service use (s. 4.48); electric vehicle charging stations too, except in a Residential zone. Water bottling is allowed in no zone (ss. 4.2, 4.2A).
Affordable housing may add homes beyond the zone's density where homes are a principal use, under s. 4.49, except in the debris flow hazard and controlled densification areas the Official Community Plan maps (its Schedules D-1 and D-2) unless s. 4.49(b)'s conditions are met (s. 4.2(y)); what that allows on a lot is the District's to say.
Spires, chimneys, flagpoles, satellite dishes, antennas, water tanks, elevator penthouses, screened ventilation equipment, rooftop deck railings up to 1.22 m, solar panels and public service structures are exempt from height limits; a main building may be 0.6 m taller where its front height point sits below the street curb on a slope of 25% to 29%, 1.2 m at 30% or more; and 1.5 m taller where the flood construction level is more than 1.5 m above its height datum, all its lived-in floors meet that level and it meets one of s. 4.10(c)'s criteria, such as one energy step above the base (s. 4.10).
Below the flood construction level an engineer sets, a home may hold only parking, entry foyers and rooms not lived in with nothing in them that floodwater would damage (s. 4.24).
No animals but household pets and guard dogs unless the zone allows them (s. 4.13). Urban agriculture, allowed in every zone, takes in hens and bees: a hen coop at most 10 m² and 2 m high, at grade in the rear yard, 3 m from any door or window of a home, behind an electric fence; beehives 2 on a lot under 929 m², 4 up to 1,394 m², 6 above, in the rear yard facing away from the nearest lot line, behind an electric fence inside a 1.8 m fence, with a sign (ss. 4.2(o), 4.33(b), (c), 4.6(e), (f)).
Outdoor lights shielded so no glare shines up, sideways or onto neighbours or roads, no brighter than the use needs and at most 3000K (2200K or amber within a 30 m riparian area); path lights at most 5 m high, parking lot lights 7.5 m (s. 4.28).
Garbage and recycling bins kept in a building, enclosure, garage or other structure; with four or more homes, a waste room of at least 9.0 m², 2.5 m across, with a 2.0 m door, a 2.4 m ceiling and clear access to the pickup point (s. 4.53).
Site-specific exceptions listed in the bylaw by legal description can add or change uses for one property, and development permit areas, the ALR and building rules apply on top. Confirm with the District of Squamish's planning department before you buy or build.
Source: Section 21 of District of Squamish Zoning Bylaw No. 2200, 2011 (summarised in our words, checked 2026-10-31); zone map: Open Government Licence – Squamish.
District of Squamish Zoning Bylaw No. 2200, 2011 applies in Squamish.
Other residential zones R-1, R-2, R-3, R-4 and R-5, the University Housing zone UH-1, the Park, Recreational, and Institutional Use zone P-3, the Ecological Reserve zone P-4, the Resource zone RE, the Downtown Commercial zone C-4, the Rural Residential zone RL-2, the Light Industrial zone I-1, the General Industrial zone I-3, the Business Park Industrial zone I-11, the Rail Transportation zone I-6 and the Comprehensive Development zones CD-35 and CD-38 zones in this bylaw
R-1 Residential 1, R-2 Residential 2, R-3 Residential 3, P-4 Ecological Reserve, RE Resource, R-4 Residential 4, R-5 Residential 5, P-3 Park, Recreational, and Institutional Use, C-4 Downtown Commercial, I-1 Light Industrial, CD-38 Comprehensive Development Zone 38 (small-lot houses), I-6 Rail Transportation, RL-2 Rural Residential 2, I-11 Business Park Industrial, CD-35 Comprehensive Development Zone 35, I-3 General Industrial.