PlaceDossier / Zoning / District of Squamish

CD-35: Comprehensive Development Zone 35

CD-35 is a zone in District of Squamish Zoning Bylaw No. 2200, 2011 (District of Squamish). Our summary of Section 40EE of the bylaw as amended to September 17, 2026.

What the zone allows

Homes allowed
Block A: one house a lot (not a modular or mobile home) of at most 162.57 m² of floor area. Block B: houses (not modular or mobile homes), apartments and townhouses, at most 20 homes in all, each at least 55.8 m² (ss. 40EE.1, 40EE.2). Where a lot is on community water and sewer and outside the ALR, a duplex is allowed where a house is (s. 4.52), and an accessory dwelling unit in any zone that allows a house (s. 4.38(a)); how either counts against Block B's 20 homes or Block A's floor area is unclear. The zone lists no secondary suite; s. 4.5 lets one sit in a single-unit dwelling, so whether a house here may have one is unclear: ask the District
Exceptions (2)
  • On one strata lot the bylaw names, no house or home occupation but a daycare, with up to 404.12 m² of floor area
  • On another strata lot the bylaw names, a café, a business office and apartment units, with up to 181.2 m² of floor area

Listed in ss. 40EE.1, 40EE.2, 40EE.11 of the bylaw.

Main uses
Block A: a house, office home occupations (s. 4.18), accessory uses. Block B: houses, apartments, townhouses, office home occupations, accessory uses; uses combined only as part of a comprehensive design (s. 40EE.1)
Smallest lot for a subdivision
275 m², 9.0 m wide, 30 m deep (25 m deep for a lot over 12 m wide), bare-land strata lots included (s. 40EE.10)
Lot coverage
50% in both blocks (s. 40EE.4)
Height limit
Block A: 10.68 m or three storeys, whichever is less; Block B: 10.68 m; accessory buildings 3.0 m, or 5.0 m where their roof slope and materials match the main building (s. 40EE.3)
Setbacks
Block A: front 6.0 m, sides 1.5 m (one side down to 0.8 m where the other side and the neighbour's facing side are 2.15 m, at least 2.95 m together; 0 m for a garage or carport built against a neighbour's), rear 3.0 m. Block B: front 6.0 m, sides 1.5 m, rear 9.15 m (s. 40EE.8). Also accessory buildings and structures: not in the front yard, 1.2 m from interior side and rear lines (a greenhouse 1.0 m), and on a corner lot the main building's exterior side setback (s. 4.4(d)); a wildlife-proof enclosure on a lot with no lane is exempt from these (s. 4.4(e)); an uncovered swimming pool not in the front or exterior side yard and 3.0 m from interior side and rear lines (s. 4.11(i)); into a setback, bay windows, chimneys, fireplaces, sunshades and sills may reach 0.61 m, eaves and awnings 0.91 m, balconies 0.76 m, steps and landings 2.04 m, an open front porch or stairs up to 2 m high 3 m into the front setback, a solar device on a building 1.83 m, covered bicycle parking on a building 1.8 m, engineer-approved exterior cladding up to 0.165 m thick; patios up to 0.62 m high, accessible ramps, arbours, trellises, poles, antennas, signs and play areas are exempt (s. 4.11); on a corner lot nothing above 0.46 m in the 6.10 m sight triangle at the corner, up to the first storey, and nothing above 0.46 m where a driveway crosses a sidewalk (s. 4.8)

The bylaw gives no statement of the zone's intent and no map of its two blocks. Block A's named lots are strata lots, so Block A reads as a bare-land strata of small-lot houses (our reading); which block a lot is in, ask the District.

Common useable open space of at least 40 m² in each block; in Block B each home also has a patio, deck or balcony of at least 10% of its floor area (s. 40EE.5). The general rule asks every CD zone for common useable open space of at least 30% of the lot for apartments and 40 m² a home for townhouses (the larger where a parcel has both), open space at grade at least 6.10 m across and no steeper than 5% (s. 4.29(a) to (c)); which governs in Block B is unclear: ask the District.

Fences and landscape screens at most 1.83 m, and 1.22 m between the front lot line and the front of the building, of stained or painted wood, brick, stone or chain link; no barbed or razor wire; electric security fencing only inside a fence at least 1.2 m high, with warning signs every 10 m and at most 10,000 volts; a fence on a retaining wall within 1.22 m of a lot line at most 2.44 m with the wall (s. 4.6(a), (c), (d), (k)) (s. 40EE.6). Everything not built on or paved is landscaped (ss. 40EE.9, 4.27(a)).

Parking (s. 40EE.7, Table 3): 2 spaces a house; townhouses and apartments 1.25 a one-bedroom, 1.75 a two-bedroom and 2 a three-bedroom home (an apartment bachelor 1), plus 0.25 a home for visitors.

A home here is most often a strata lot: what an owner may do with it (renting it, changes) is in the strata's bylaws as well, so read them.

Short-term rental (stays under 90 days, bed and breakfasts included) is allowed in every CD zone where homes are allowed, though not among this zone's own uses, but only in the operator's principal residence (where they live at least 183 days a year), with a District licence, and never in a secondary suite, accessory dwelling unit, accessory building, vehicle or tent (ss. 4.46(a) to (d), (g)); one principal residence per person, and the whole home rented short term at most 182 days a year; parking under Section 41 and the building and fire bylaws' occupancy limits apply (ss. 4.46(e), (f); definitions in Section 1).

Every zone also allows repairs, a site office while a building goes up, and, with a building permit, a covenant on title and security, living in an existing or temporary building while a new home is built (it is removed or converted once the home is done); water, sewer and drainage works, pipelines, power and telephone lines, streets and lanes, street lights and furniture, recycling bins, voting places and campaign offices for a time, interpretive signs, public art, parks, playgrounds, trails, urban agriculture, a neighbourhood energy utility, assisted living, community care facilities, transitional housing, emergency shelters and public service use (s. 4.48); electric vehicle charging stations too, except in a Residential zone. Water bottling is allowed in no zone (ss. 4.2, 4.2A).

Affordable housing may add homes beyond the zone's density where homes are a principal use, under s. 4.49, except in the debris flow hazard and controlled densification areas the Official Community Plan maps (its Schedules D-1 and D-2) unless s. 4.49(b)'s conditions are met (s. 4.2(y)); what that allows on a lot is the District's to say.

Spires, chimneys, flagpoles, satellite dishes, antennas, water tanks, elevator penthouses, screened ventilation equipment, rooftop deck railings up to 1.22 m, solar panels and public service structures are exempt from height limits; a main building may be 0.6 m taller where its front height point sits below the street curb on a slope of 25% to 29%, 1.2 m at 30% or more; and 1.5 m taller where the flood construction level is more than 1.5 m above its height datum, all its lived-in floors meet that level and it meets one of s. 4.10(c)'s criteria, such as one energy step above the base (s. 4.10).

Below the flood construction level an engineer sets, a home may hold only parking, entry foyers and rooms not lived in with nothing in them that floodwater would damage (s. 4.24).

A lot registered before the bylaw that is smaller than the zone's minimum may still be used if it meets every other rule of the zone (s. 4.9).

No animals but household pets and guard dogs unless the zone allows them (s. 4.13). Urban agriculture, allowed in every zone, takes in hens and bees: a hen coop at most 10 m² and 2 m high, at grade in the rear yard, 3 m from any door or window of a home, behind an electric fence; beehives 2 on a lot under 929 m², 4 up to 1,394 m², 6 above, in the rear yard facing away from the nearest lot line, behind an electric fence inside a 1.8 m fence, with a sign (ss. 4.2(o), 4.33(b), (c), 4.6(e), (f)).

Outdoor lights shielded so no glare shines up, sideways or onto neighbours or roads, no brighter than the use needs and at most 3000K (2200K or amber within a 30 m riparian area); path lights at most 5 m high, parking lot lights 7.5 m (s. 4.28).

Garbage and recycling bins kept in a building, enclosure, garage or other structure; with four or more homes, a waste room of at least 9.0 m², 2.5 m across, with a 2.0 m door, a 2.4 m ceiling and clear access to the pickup point (s. 4.53).

An apartment building of more than 20 homes has 2.0 m² of indoor amenity space a home, in one place (s. 4.43).

Site-specific exceptions listed in the bylaw by legal description can add or change uses for one property, and development permit areas, the ALR and building rules apply on top. Confirm with the District of Squamish's planning department before you buy or build.

Source: Section 40EE of District of Squamish Zoning Bylaw No. 2200, 2011 (summarised in our words, checked 2026-10-31); zone map: Open Government Licence – Squamish.

District of Squamish Zoning Bylaw No. 2200, 2011 applies in Squamish.

Other residential zones R-1, R-2, R-3, R-4 and R-5, the University Housing zone UH-1, the Park, Recreational, and Institutional Use zone P-3, the Ecological Reserve zone P-4, the Resource zone RE, the Downtown Commercial zone C-4, the Rural Residential zone RL-2, the Light Industrial zone I-1, the General Industrial zone I-3, the Business Park Industrial zone I-11, the Rail Transportation zone I-6 and the Comprehensive Development zones CD-35 and CD-38 zones in this bylaw

R-1 Residential 1, R-2 Residential 2, R-3 Residential 3, P-4 Ecological Reserve, RE Resource, R-4 Residential 4, UH-1 University Housing 1, R-5 Residential 5, P-3 Park, Recreational, and Institutional Use, C-4 Downtown Commercial, I-1 Light Industrial, CD-38 Comprehensive Development Zone 38 (small-lot houses), I-6 Rail Transportation, RL-2 Rural Residential 2, I-11 Business Park Industrial, I-3 General Industrial.