PlaceDossier / Zoning / District of Squamish
P-3: Park, Recreational, and Institutional Use
P-3 is a zone in District of Squamish Zoning Bylaw No. 2200, 2011 (District of Squamish). Our summary of Section 19 of the bylaw as amended to September 17, 2026.
What the zone allows
- Homes allowed
- No house: the only home the zone allows is one caretaker dwelling, accessory to the lot's main use, of at most 70 m² (90 m² on a lot of 0.2 ha or more if a tenth of its energy is made on site), never on its own strata title (ss. 19.1(k), 4.3)
- Main uses
- Assembly, a campground, a child care facility, a college or university, golf courses, parks and playgrounds, community and event storage, recreational facilities; accessory recreational facilities, a caretaker dwelling and accessory uses (s. 19.1)
Exceptions (1)
- Agriculture on one parcel the bylaw's Schedule A maps
Listed in s. 19.1(i) of the bylaw.
- Smallest lot for a subdivision
- No minimum set in the zone
- Lot coverage
- 33% (s. 19.3)
- Height limit
- Main building 10.68 m; accessory buildings 4.58 m (s. 19.2)
- Setbacks
- Main building: front 7.62 m, rear 9.15 m, sides 3.05 m (7.62 m on a street) (s. 19.4). Also accessory buildings and structures: not in the front yard, 1.2 m from interior side and rear lines (a greenhouse 1.0 m), and on a corner lot the main building's exterior side setback (s. 4.4(d)); on the one parcel where agriculture is allowed, if it is outside the primary and secondary floodways the Official Community Plan maps (its Schedule L), a building used only for farming may stand in the front yard, 1.0 m from the front line (s. 4.4(d)(vi)); an uncovered swimming pool not in the front or exterior side yard and 3.0 m from interior side and rear lines (s. 4.11(i)); into a setback, bay windows, chimneys, fireplaces, sunshades and sills may reach 0.61 m, eaves and awnings 0.91 m, balconies 0.76 m, steps and landings 2.04 m, an open front porch or stairs up to 2 m high 3 m into the front setback, a solar device on a building 1.83 m, covered bicycle parking on a building 1.8 m, engineer-approved exterior cladding up to 0.165 m thick; patios up to 0.62 m high, accessible ramps, arbours, trellises, poles, antennas, signs and play areas are exempt (s. 4.11); on a corner lot nothing above 0.46 m in the 6.10 m sight triangle at the corner, up to the first storey, and nothing above 0.46 m where a driveway crosses a sidewalk (s. 4.8); no building or structure but signs within 4.57 m of the Highway 99 right of way (s. 4.20)
The zone is for public land serving the District's school, park and recreation needs (s. 19). Most of it is parks, schools and public grounds, so a lot here is rarely sold as a home lot; ask the District what a lot here may be used for before you buy.
Accessory buildings: one per lot of up to 140 m² for a park use, plus up to five of 10 m² or less and 3 m high, not in the front yard (ss. 4.4, 19.7). Barbed or razor wire, at most three strands, only above 1.83 m (s. 4.6(c)); the fence limits of s. 4.6(a) don't name this zone (ss. 19.5, 4.6).
Every part of the lot not used for buildings, outdoor display, parking or loading is landscaped and kept permeable; healthy trees and shrubs kept through construction unless the Building Inspector agrees they must go; new planting native or water-conserving, no invasive species (s. 4.27(a), (c), (d)); Beside a lot in a Residential zone, a fence or landscape screen 1.83 m high (plants may be taller) along the shared line unless a building stands on it; garbage containers over 0.5 m³ out of sight of a street; heating, cooling and ventilation equipment screened by a solid wall. Across a lane from a residential lot, s. 4.7(c) puts a 1.22 m to 1.83 m fence or screen along the lane on the owner of the residential lot, which reads as a slip for the non-residential one: ask the District (s. 4.7(a) to (c), (e), (g)).
Parking (s. 19.6, Table 3): parks and public use 2.7 spaces per 100 m² of floor area, an elementary school 2 a classroom, a secondary school 5.
Every zone also allows repairs, a site office while a building goes up, and, with a building permit, a covenant on title and security, living in an existing or temporary building while a new home is built (it is removed or converted once the home is done); water, sewer and drainage works, pipelines, power and telephone lines, streets and lanes, street lights and furniture, recycling bins, voting places and campaign offices for a time, interpretive signs, public art, parks, playgrounds, trails, urban agriculture, a neighbourhood energy utility, assisted living, community care facilities, transitional housing, emergency shelters and public service use (s. 4.48); electric vehicle charging stations too, except in a Residential zone. Water bottling is allowed in no zone (ss. 4.2, 4.2A).
Spires, chimneys, flagpoles, satellite dishes, antennas, water tanks, elevator penthouses, screened ventilation equipment, rooftop deck railings up to 1.22 m, solar panels and public service structures are exempt from height limits; a main building may be 0.6 m taller where its front height point sits below the street curb on a slope of 25% to 29%, 1.2 m at 30% or more; and 1.5 m taller where the flood construction level is more than 1.5 m above its height datum, all its lived-in floors meet that level and it meets one of s. 4.10(c)'s criteria, such as one energy step above the base (s. 4.10).
A lot registered before the bylaw that is smaller than the zone's minimum may still be used if it meets every other rule of the zone (s. 4.9).
Outdoor lights shielded so no glare shines up, sideways or onto neighbours or roads, no brighter than the use needs and at most 3000K (2200K or amber within a 30 m riparian area); path lights at most 5 m high, parking lot lights 7.5 m (s. 4.28).
Short-term rental is allowed only in a dwelling unit that is the operator's principal residence, never in a caretaker dwelling (s. 4.46), so it isn't open in this zone (our reading).
Site-specific exceptions listed in the bylaw by legal description can add or change uses for one property, and development permit areas, the ALR and building rules apply on top. Confirm with the District of Squamish's planning department before you buy or build.
Source: Section 19 of District of Squamish Zoning Bylaw No. 2200, 2011 (summarised in our words, checked 2026-10-31); zone map: Open Government Licence – Squamish.
District of Squamish Zoning Bylaw No. 2200, 2011 applies in Squamish.
P-3 in other BC bylaws: what P-3 allows in each of the 16 we've summarised.
Other residential zones R-1, R-2, R-3, R-4 and R-5, the University Housing zone UH-1, the Park, Recreational, and Institutional Use zone P-3, the Ecological Reserve zone P-4, the Resource zone RE, the Downtown Commercial zone C-4, the Rural Residential zone RL-2, the Light Industrial zone I-1, the General Industrial zone I-3, the Business Park Industrial zone I-11, the Rail Transportation zone I-6 and the Comprehensive Development zones CD-35 and CD-38 zones in this bylaw
R-1 Residential 1, R-2 Residential 2, R-3 Residential 3, P-4 Ecological Reserve, RE Resource, R-4 Residential 4, UH-1 University Housing 1, R-5 Residential 5, C-4 Downtown Commercial, I-1 Light Industrial, CD-38 Comprehensive Development Zone 38 (small-lot houses), I-6 Rail Transportation, RL-2 Rural Residential 2, I-11 Business Park Industrial, CD-35 Comprehensive Development Zone 35, I-3 General Industrial.