What the zone allows
- Homes allowed
- Street-oriented village homes: one home in each principal building, joined side by side by party walls to its neighbours, each on its own lot (a strata lot counts) facing a street with a lane behind; at most eight buildings joined in a row; one principal building per lot unless the lot is stratified (Part 2; s. 1006(3)(a), (7)). The zone lists no secondary suite or other accessory dwelling unit
- Main uses
- Street-oriented village homes; boarding, home occupations and accessory residential uses (s. 1006(2))
- Smallest lot for a subdivision
- 210 m² for a fee-simple lot; each principal building at least 4.5 m wide (s. 1006(4))
- Lot coverage
- 45% for all buildings and structures (s. 1006(6))
- Height limit
- Homes 7.3 m, or 11.0 m where at least 80% of the roof is pitched 3 in 12 or steeper; detached accessory buildings and garages 3.7 m, 4.6 m with a roof of 4 in 12 or steeper (s. 1006(10))
- Setbacks
- Homes, and accessory buildings attached or within 1.6 m of them: front 4.0 m, rear 6.2 m, interior sides 0.0 m where the home shares a side wall with its neighbour and 1.4 m otherwise, street side 3.0 m (3.8 m for those accessory buildings). Detached accessory buildings, only in the rear yard: rear 6.2 m, sides 1.2 m, street side 3.8 m; detached garages rear 1.2 m, street side 3.8 m and, in the table, 0.0 m from an inside side line; but s. 1006(8)(h) speaks of reducing that side setback to 0.0 m only for a garage joined along its whole side wall to the neighbour's (0.9 m on a corner lot), so which applies is unclear: ask the City. Detached buildings stand at least 6.0 m behind the home. At least half the home's ground-floor width sits within 1.0 m of the front setback; a covered porch may reach 1.7 m into it (s. 1006(8), (9))
The zone is for street-oriented homes joined in rows, on lots of at least 210 m² (s. 1006(1)).
Floor area ratio 0.9 for the homes; at most 48 homes a hectare, or 89 for special needs or affordable housing on City or non-profit land, where a building may hold more than one home (s. 1006(5); Part 2).
Parking is reached from the lane only, in the rear yard, never in the street side setback; a detached garage at most 7.0 m along any wall (ss. 1006(3)(a)(ii), (9), (11)). Two spaces a home, at most a third of them in tandem; none inside a Transit-Oriented Area (s. 706(1)). Each home's space needs an energized level 2 outlet for an electric vehicle (s. 714).
No in-ground swimming pool anywhere on the lot (s. 1006(13)(b)). Northeast Coquitlam's landscaping rules in Part 5 apply (s. 1006(13)(a)).
Subdivision without City water and sewer: at least 1.25 ha (0.4 ha with City water but no sewer) (s. 602(2)). The Approving Officer may cut the zone's minimum width by up to 10% for the last lot of a subdivision (s. 603(2)). A lot made to house a relative under the Local Government Act is at least 2.5 ha (s. 602(4)(b)); a bare land strata needs a road reaching each lot (s. 601(2)).
Boarding: at most two boarders in a home; a bed and breakfast counts as boarding, for one family or two boarders, inside the building (s. 508(1)). Outside a Transit-Oriented Area, one parking space for each boarder's room (s. 706(1)(a)(ix)).
Home occupations: licensed, run by at least one person who lives there with at most one employee from elsewhere, in a principal home or an accessory dwelling unit, inside the home or an accessory residential building (child care may use the outdoors), at most 40% of that home's floor area; no sales of goods made elsewhere, no outdoor display or storage, nothing that shows from outside but an unlit sign of up to 0.2 m², no more traffic or parking than the zone usually sees, no dangerous goods, no animals kept for gain or bred, no vehicle repair, and never adult entertainment, an adult video store, cheque cashing, scrap metal dealing or a tattoo parlour (s. 508(3)).
Tourist accommodation (stays of 60 days or less) isn't a residential use under the bylaw (Part 2) and isn't listed in this zone; a bed and breakfast counts as boarding (above). Ask the City whether and how a home here may be rented by the night.
Setbacks grow by 3.5 m along a major arterial street the bylaw lists, less any widening already taken (s. 518), and on a lot of 280 m² or more are measured from a future street or lane line the Approving Officer or Servicing Officer requires (s. 517(1)). Chimneys, bay windows and ornamental features may reach 0.6 m into a setback, 3.0 m along a wall in all, bay windows never into an RS, R or RT zone's interior side setback unless beside a lane; eaves, steps, porches, balconies and canopies 0.6 m into a setback from an interior lot line and 1.5 m into the others, keeping 0.6 m clear; an in-ground pool, where the zone allows one, anywhere outside the arterial, flood, slope and streamside limits (s. 514). A zone's own rules can narrow these (see its notes). Chimneys, antennas, elevator and stair towers, skylights and the like may pass the height limit (s. 515). The rest of the lot is landscaped (s. 505).
Every zone also allows streets and micromobility paths, utility poles, lines, traffic controls, bus shelters and underground utilities (no compressor or pumping station buildings unless the zone allows them), rapid transit stations, parks and playgrounds, accessory parking and loading, and one satellite dish (s. 502). A satellite dish over 0.8 m across stands behind the principal building, 1.2 m from rear and side lines and 3.8 m from a street side line, and never on the roof of a building of under four storeys with a home in it (s. 520).
A temporary building may not be a home and follows the zone's use, density, parking, setbacks and height; a construction trailer is exempt (s. 504).
Flood and slope (s. 519): no building within 30 m of the natural boundary of the DeBoville Slough or the Brunette, Coquitlam, Fraser or Pitt River, or 15 m of another watercourse draining 2 km² or more whose bed lies 0.6 m or more below the land beside it; a habitable floor's underside at the flood construction level a qualified professional sets inside the floodplain shown on Schedule G (or a level set by a covenant on title), and 1.5 m above such a watercourse's natural boundary outside it, with exceptions for renovations without an addition, additions under 25% of the floor area, garages and carports, and farm buildings in the Agricultural Land Reserve other than homes; Council may exempt a lot the rules make impracticable to build on, on a professional's report and a covenant. Building (or placing a shed, pool, drainage work or the like) on or next to a slope steeper than 18 degrees (next to it reaching out by two to three times the slope's height), within 3 m to the side or 5 m to the front or back of its crest or toe, or on or next to a slope with known problems, needs a Slope Hazard Assessment first (s. 519(3)). Within 30 m of a stream with salmonids, game fish or listed species at risk (farther in a ravine), the City approves residential, commercial or industrial development only where it stays outside a streamside area the City has mapped, on an assessment report under the Riparian Areas Protection Regulation, or with a federal Fisheries Act authorization; repairs on an existing footprint are left out (s. 523).
Prohibited in every zone unless the bylaw allows it elsewhere: living in a mobile home, tent, trailer or recreational vehicle; casino or electronic gaming; pawnshops, massage parlours, escort services and exotic dancing; growing, processing, storing or selling cannabis; more than one person per 10 m² of a home, or more than one family or three unrelated people in one, except as boarding; parking or storing a vehicle over 4,500 kg gross (recreational and passenger vehicles excepted); and using a lot the City finds has no usable street access (s. 503).
Every home is over 29 m² (s. 522); a bedroom at least 8.0 m² and 2.4 m across, walled off with a door (s. 531).
New homes need an enclosed space for garbage, green waste and recycling carts (for small-scale homes at least 0.9 by 1.4 by 1.3 m a home with its own carts, larger where carts are shared; for apartments, and townhouses with a common area, the greater of 7.5 m² and 0.29 m² a home, up to 50 m²); a separate storage structure never in the front yard; a garage can count; the City may accept less (ss. 509, 514(3)).
A boat may be built only inside a building or fully screened from outside the lot, never in front of the building or beside it on the street side (s. 508(4)).
A show home or sales centre may market a development with a development permit or final subdivision approval, inside the zone's setbacks and height, 1.5 m from active construction, with at least two parking spaces, on the development's own site and gone before full occupancy unless it is in an existing commercial unit or building on a commercially zoned lot (s. 502(4)).
On a residential lot's parking: contractor's equipment only inside a building; at most two recreational vehicles or boat trailers unless inside; none over 3.7 m high unless inside; one over 7.6 m long only inside or where the driveway (with any parking pad) is longer, and no longer than the driveway or 15.2 m; in a side setback only behind a solid fence or planting at least 1.8 m high. A commercial vehicle only inside, or, if 7.6 m long or less, behind such a screen in a side setback or on a driveway longer than 7.6 m; a longer one only inside or on a longer driveway, up to its length and 15.2 m; one over 3.7 m high only inside. No recreational or commercial vehicle the occupant or owner doesn't own (s. 508(5)).
Fences up to 1.3 m, or 1.8 m behind the front face of the building; a park in a residential zone 1.3 m along the front line, 1.8 m elsewhere (s. 516(2), (3)). Within 6 m of a corner lot's street corner, fences, walls and hedges at most 1 m, with trees trimmed clear between 1 and 2 m, and none in the 3 m by 3 m corner at a lane or street intersection (s. 516(1)). A retaining wall at most 1.2 m (2.4 m when built as a subdivision condition or with the City's leave), stepped walls 1.2 m apart; a fence on a wall over 1.2 m at most 1.8 m, 3 m together (s. 516(4), (5)). Fences are wood, masonry (not poured concrete), metal or precast panels (Part 2). In the R zones a retaining wall stands 0.6 m back from the front and street side lines and the corner, with a planted screen in front (s. 516(4), (5)). No barbed or razor wire (s. 516(6)).
Heat pumps, air conditioners, generators and pool equipment may sit anywhere on the lot, but for small-scale and village homes the bylaw places them at least 1.0 m from the required interior side setback (whether measured from the lot line or from the setback's inner edge is unclear: ask the City), with heating and cooling vents not venting toward an interior side line; pool equipment at most 1.3 m high (s. 514(5)).
Chimneys, bay windows, heating or ventilating equipment and ornamental features may not reach into the interior side setbacks at the first storey (s. 1006(8)(g)).
Site-specific exceptions listed in the bylaw by legal description can add or change uses for one property, and development permit areas, the ALR and building rules apply on top. Confirm with the City of Coquitlam's planning and development department before you buy or build.
Source: Section 1006 of City of Coquitlam Zoning Bylaw No. 3000, 1996 (summarised in our words, checked 2026-10-30); zone map: Open Government Licence – Coquitlam.
City of Coquitlam Zoning Bylaw No. 3000, 1996 applies in Coquitlam.
Other low-density residential (RS-2, R-1 to R-4, RTM-1, RT-2), legacy single family and infill (RS-1, RS-3, RS-4, RT-1, RT-3), Agricultural and Resource (A-3), Service Commercial (CS-1), General Commercial (C-2), General Industrial (M-1), Industrial Business (M-2), Civic Institutional (P-1), Special Institutional (P-2), Special Recreation (P-3) and Special Park (P-5) zones, apartment and townhouse zones RM-1 and RM-2, and the Comprehensive Development zone CD-29 zones in this bylaw
RS-2 Rural Residential, R-1 Small-Scale Residential, R-2 Compact Small-Scale Residential, R-3 Transitional Small-Scale Residential, R-4 Intensive Small-Scale Residential, RT-2 Townhouse Residential, RS-1 One-Family Residential, RS-3 One-Family Residential, RS-4 One-Family Compact Residential, RT-1 Infill Residential, RT-3 Multiplex Residential, M-1 General Industrial, M-2 Industrial Business, P-1 Civic Institutional, P-5 Special Park, A-3 Agricultural and Resource, CS-1 Service Commercial, C-2 General Commercial, CD-29 Comprehensive Development Zone-29 (zero-lot-line small-scale residential), RM-1 Two-Storey Low Density Apartment Residential, RM-2 Three-Storey Medium Density Apartment Residential, P-3 Special Recreation, P-2 Special Institutional.