CD-29 is a zone in City of Coquitlam Zoning Bylaw No. 3000, 1996 (City of Coquitlam). Our summary of Section 2129 of the bylaw as amended to July 27, 2026.

What the zone allows

Homes allowed
Up to 4 homes on a lot: at most two principal homes (a house, or one half of a pair joined by a party wall to the next lot's) and two accessory dwelling units; on a lot of 280 m² or less, 3 homes, at most two of them principal (s. 2129(3)). One principal building a lot (s. 2129(7))
Main uses
Small-scale residential homes; boarding, accessory dwelling units (detached ones in the rear yard), home occupations and off-street parking (s. 2129(2), (9))
Smallest lot for a subdivision
270 m², 9.0 m wide, 30.0 m deep (s. 2129(4))
Lot coverage
45% for all buildings (s. 2129(6)); the principal building at most 225 m² and all buildings 0.6 times the lot area, each up to 25 m² more for parking; floor with a ceiling over 3.5 m counts twice; the top storey at most 85% of the one below (ss. 2129(5), (11))
Height limit
9.0 m, with a roof of 4 in 12 or steeper over at least 80% of it; detached accessory buildings 3.7 m, 4.6 m with such a roof (s. 2129(10))
Setbacks
Principal building: front 4.0 m, rear 6.0 m, sides 1.2 m, street side 1.2 m; one interior side may be 0.0 m, joined by a party wall to the next lot's building, on a corner lot or where the other side is at least 1.8 m. Attached accessory buildings: front and rear 6.0 m, sides 1.2 m; detached accessory buildings 1.6 m or more from the house: front 6.0 m, rear and sides 1.2 m. Covered front porches may come 1.7 m into the front setback; heat pumps and generators 2.2 m from an interior side (s. 2129(8))
Exceptions (1)
  • Street side 3.0 m along the three arterial streets the zone names

Listed in s. 2129(8)(b) of the bylaw.

The zone is for zero-lot-line small-scale homes on fee simple lots (s. 2129(1)). Two lots whose houses share a party wall are built as one development, with a development permit (s. 2129(13)(b)).

At least 35% of the house's front is 1.0 m ahead of the garage door; all parking may be in tandem (s. 2129(9), (12)). At least 10 m² of the front yard is planted, with a tree; no in-ground swimming pool (s. 2129(13)).

An accessory dwelling unit (a secondary suite, carriage house or garden cottage) counts as one of the zone's homes (Part 2). A detached building holding only an accessory dwelling unit is a principal building, not an accessory one, so it takes the zone's principal setbacks (Part 2).

Parking: one space for a home under 79 m², 1.5 from 79 to 158 m², 2 for a bigger one, all of which may be in tandem; inside a Transit-Oriented Area the bylaw requires none for homes (s. 706(1)). A space with no aisle is 2.6 by 5.8 m; on a lot of six or fewer small-scale homes, a driveway for two-way alternating traffic is at least 3.5 m wide where the lot is under 12.5 m wide, 4.0 m from 12.5 m to under 13.0 m, 4.5 m from 13.0 m (3.5 m one-way), 4.2 m clear overhead, kept clear of window wells, stairs and the like (s. 705(1), (2)(b)); an accessory dwelling unit's own space and driveway may be permeable pavers, or another compact, dust-free, drained surface sloping no more than 10% (s. 705(8)(b)).

Boarding: at most two boarders in a home; a bed and breakfast counts as boarding, for one family or two boarders, inside the building (s. 508(1)). Outside a Transit-Oriented Area, one parking space for each boarder's room (s. 706(1)(a)(ix)).

Home occupations: licensed, run by at least one person who lives there with at most one employee from elsewhere, in a principal home or an accessory dwelling unit, inside the home or an accessory residential building (child care may use the outdoors), at most 40% of that home's floor area; no sales of goods made elsewhere, no outdoor display or storage, nothing that shows from outside but an unlit sign of up to 0.2 m², no more traffic or parking than the zone usually sees, no dangerous goods, no animals kept for gain or bred, no vehicle repair, and never adult entertainment, an adult video store, cheque cashing, scrap metal dealing or a tattoo parlour (s. 508(3)).

Tourist accommodation (stays of 60 days or less) isn't a residential use under the bylaw (Part 2) and isn't listed in this zone; a bed and breakfast counts as boarding (above). Ask the City whether and how a home here may be rented by the night.

Setbacks grow by 3.5 m along a major arterial street the bylaw lists, less any widening already taken (s. 518), and on a lot of 280 m² or more are measured from a future street or lane line the Approving Officer or Servicing Officer requires (s. 517(1)). Chimneys, bay windows and ornamental features may reach 0.6 m into a setback, 3.0 m along a wall in all, bay windows never into an RS, R or RT zone's interior side setback unless beside a lane; eaves, steps, porches, balconies and canopies 0.6 m into a setback from an interior lot line and 1.5 m into the others, keeping 0.6 m clear; an in-ground pool, where the zone allows one, anywhere outside the arterial, flood, slope and streamside limits (s. 514). A zone's own rules can narrow these (see its notes). Chimneys, antennas, elevator and stair towers, skylights and the like may pass the height limit (s. 515). The rest of the lot is landscaped (s. 505).

Every zone also allows streets and micromobility paths, utility poles, lines, traffic controls, bus shelters and underground utilities (no compressor or pumping station buildings unless the zone allows them), rapid transit stations, parks and playgrounds, accessory parking and loading, and one satellite dish (s. 502). A satellite dish over 0.8 m across stands behind the principal building, 1.2 m from rear and side lines and 3.8 m from a street side line, and never on the roof of a building of under four storeys with a home in it (s. 520).

A temporary building may not be a home and follows the zone's use, density, parking, setbacks and height; a construction trailer is exempt (s. 504).

Flood and slope (s. 519): no building within 30 m of the natural boundary of the DeBoville Slough or the Brunette, Coquitlam, Fraser or Pitt River, or 15 m of another watercourse draining 2 km² or more whose bed lies 0.6 m or more below the land beside it; a habitable floor's underside at the flood construction level a qualified professional sets inside the floodplain shown on Schedule G (or a level set by a covenant on title), and 1.5 m above such a watercourse's natural boundary outside it, with exceptions for renovations without an addition, additions under 25% of the floor area, garages and carports, and farm buildings in the Agricultural Land Reserve other than homes; Council may exempt a lot the rules make impracticable to build on, on a professional's report and a covenant. Building (or placing a shed, pool, drainage work or the like) on or next to a slope steeper than 18 degrees (next to it reaching out by two to three times the slope's height), within 3 m to the side or 5 m to the front or back of its crest or toe, or on or next to a slope with known problems, needs a Slope Hazard Assessment first (s. 519(3)). Within 30 m of a stream with salmonids, game fish or listed species at risk (farther in a ravine), the City approves residential, commercial or industrial development only where it stays outside a streamside area the City has mapped, on an assessment report under the Riparian Areas Protection Regulation, or with a federal Fisheries Act authorization; repairs on an existing footprint are left out (s. 523).

Prohibited in every zone unless the bylaw allows it elsewhere: living in a mobile home, tent, trailer or recreational vehicle; casino or electronic gaming; pawnshops, massage parlours, escort services and exotic dancing; growing, processing, storing or selling cannabis; more than one person per 10 m² of a home, or more than one family or three unrelated people in one, except as boarding; parking or storing a vehicle over 4,500 kg gross (recreational and passenger vehicles excepted); and using a lot the City finds has no usable street access (s. 503).

Every home is over 29 m² (s. 522); a bedroom at least 8.0 m² and 2.4 m across, walled off with a door (s. 531).

New homes need an enclosed space for garbage, green waste and recycling carts (for small-scale homes at least 0.9 by 1.4 by 1.3 m a home with its own carts, larger where carts are shared; for apartments, and townhouses with a common area, the greater of 7.5 m² and 0.29 m² a home, up to 50 m²); a separate storage structure never in the front yard; a garage can count; the City may accept less (ss. 509, 514(3)).

A boat may be built only inside a building or fully screened from outside the lot, never in front of the building or beside it on the street side (s. 508(4)).

A show home or sales centre may market a development with a development permit or final subdivision approval, inside the zone's setbacks and height, 1.5 m from active construction, with at least two parking spaces, on the development's own site and gone before full occupancy unless it is in an existing commercial unit or building on a commercially zoned lot (s. 502(4)).

Section 516's 1.3 m fence limit names Parts 10, 12 and 22 and a few other zones, not CD zones, so the 3.1 m limit for other zones reads as applying here (our reading; ask the City). Within 6 m of a corner lot's street corner, fences, walls and hedges at most 1 m, with trees trimmed clear between 1 and 2 m, and none in the 3 m by 3 m corner at a lane or street intersection (s. 516(1)). A retaining wall at most 1.2 m (2.4 m when built as a subdivision condition or with the City's leave), stepped walls 1.2 m apart; a fence on a wall over 1.2 m at most 1.8 m, 3 m together (s. 516(4), (5)). Fences are wood, masonry (not poured concrete), metal or precast panels (Part 2). No barbed or razor wire (s. 516(6)).

On a lot of small-scale homes a clear path 0.9 m wide and 2.1 m high stays open along at least one interior side line, whatever projections the setbacks allow (s. 514(12)).

Small-scale homes (a house among them: Part 2) may go on a lot smaller than the zone's minimum only if it (a strata lot included) was registered before June 30, 2025 and is on City water and sewer; a house may also go on such a lot (not a strata lot) registered before September 27, 1971 that has no City water or sewer, once the Medical Health Officer has approved its water supply and septic system in writing (s. 511(2), (3)).

Of the projections s. 514(1) and (2) allow, only eaves may reach into an interior side setback here (s. 2129(8)(f)).

Site-specific exceptions listed in the bylaw by legal description can add or change uses for one property, and development permit areas, the ALR and building rules apply on top. Confirm with the City of Coquitlam's planning and development department before you buy or build.

Source: Section 2129 of City of Coquitlam Zoning Bylaw No. 3000, 1996 (summarised in our words, checked 2026-10-30); zone map: Open Government Licence – Coquitlam.

City of Coquitlam Zoning Bylaw No. 3000, 1996 applies in Coquitlam.

Other low-density residential (RS-2, R-1 to R-4, RTM-1, RT-2), legacy single family and infill (RS-1, RS-3, RS-4, RT-1, RT-3), Agricultural and Resource (A-3), Service Commercial (CS-1), General Commercial (C-2), General Industrial (M-1), Industrial Business (M-2), Civic Institutional (P-1), Special Institutional (P-2), Special Recreation (P-3) and Special Park (P-5) zones, apartment and townhouse zones RM-1 and RM-2, and the Comprehensive Development zone CD-29 zones in this bylaw

RS-2 Rural Residential, R-1 Small-Scale Residential, R-2 Compact Small-Scale Residential, R-3 Transitional Small-Scale Residential, R-4 Intensive Small-Scale Residential, RTM-1 Street-Oriented Village Home Residential, RT-2 Townhouse Residential, RS-1 One-Family Residential, RS-3 One-Family Residential, RS-4 One-Family Compact Residential, RT-1 Infill Residential, RT-3 Multiplex Residential, M-1 General Industrial, M-2 Industrial Business, P-1 Civic Institutional, P-5 Special Park, A-3 Agricultural and Resource, CS-1 Service Commercial, C-2 General Commercial, RM-1 Two-Storey Low Density Apartment Residential, RM-2 Three-Storey Medium Density Apartment Residential, P-3 Special Recreation, P-2 Special Institutional.