RM-2: Residential Town House

RM-2 is a zone in Anglemont Zoning Bylaw No. 650 (Columbia Shuswap Regional District). Our summary of Section 5.8 of the bylaw as amended to July 18, 2024.

What the zone allows

Homes allowed
Row houses and multi-unit buildings, up to 77 homes per hectare
Main uses
Row houses, multi-unit housing
Smallest lot for a subdivision
1,000 m² with community sewer, 4,000 m² otherwise (20 m wide)
Lot coverage
30%
Height limit
Main buildings 11.5 m, accessory buildings 6 m
Setbacks
Front 6 m for row houses, 5 m for other buildings; interior side 2 m; exterior side 4.5 m; rear 7 m (3 m for accessory buildings)

Each row house is at least 60 m² (net) and each apartment at least 40 m². Accessory buildings up to 55 m² (gross).

Multi-unit buildings need one RV-sized parking space for every 8 spaces (s. 4.8).

Secondary dwelling units and home businesses aren't listed uses in this zone.

Vacation rental isn't a listed use in this zone. The CSRD says a Temporary Use Permit, usually for up to three years at first, is its usual route for a short-term rental the zoning doesn't allow, with a zoning amendment the other (the CSRD's short-term rentals page, checked October 3, 2026). Ask the CSRD before renting short term.

Floodplain (ss. 3.5 and 3.6): no buildings within 15 m of Shuswap Lake's mean annual high water mark (348.3 m) or of another watercourse; floors used for living or for goods floodwater could damage sit above 351 m on the lake and 1.5 m above other watercourses. Garages, small additions, docks and accessory buildings with no living space are exempt from parts of this, and the CSRD asks for a surveyor's certificate.

Nothing closer than 4.5 m to a provincial highway right of way without a Ministry of Transportation permit (s. 3.2(l)). On a corner, no fence, plant or structure over 0.6 m within the sight triangle, 6 m back from the intersection (s. 3.2(j), (k)).

Allowed in a setback (s. 3.2): wheelchair ramps, utility and lighting poles and anything below finished ground; steps, signs and landscaping such as a trellis or pond no closer than 1 m to a side line; eaves and gutters no closer than 1 m to any line; hot tubs and uncovered pools not between the main building and the front line and, our reading of a run-together clause, no closer than 2 m to other lines; fences up to 2.4 m and retaining walls up to 1.5 m outside the sight triangle; stepped landscape walls at least 1.5 m apart, but not beside a section 42 road under the Transportation Act or in the sight triangle.

Chimneys, flag poles, utility and lighting poles and community water tanks may go up to 20% over the height limit; antennas and farm buildings and structures have no limit (s. 3.1).

Site-specific exceptions listed in the bylaw by legal description can add or change uses for one property, and development permit areas, the ALR and building rules apply on top. Confirm with the CSRD's planning department before you buy or build.

Source: Anglemont Zoning Bylaw No. 650 (summarised in our words, checked 2026-10-30); Short-Term Rentals, Columbia Shuswap Regional District (checked 2026-10-03); zone map: Open Government Licence – Columbia Shuswap Regional District.

Anglemont Zoning Bylaw No. 650 applies in Columbia-Shuswap, Electoral Area F.

RM-2 in other BC bylaws: what RM-2 allows in each of the 11 we've summarised.

Other zones in this bylaw

RR-60 Rural Large Lot, RR-4 Rural Small Lot, CR Country Residential, RS-1 Residential, RS-5 Residential Summer Home, CG-2 General Commercial, P-4 Recreational.