PlaceDossier / Zoning / City of Penticton

RM3: Medium Density Multiple Housing

RM3 is a zone in City of Penticton Zoning Bylaw No. 2024-22 (City of Penticton). Our summary of Section 10.5 of the bylaw as amended to July 14, 2026.

What the zone allows

Homes allowed
Apartments and townhouses up to 1.6 FAR; congregate housing and extended care; secondary suites
Main uses
Apartments, townhouses, congregate housing, extended care residence, major day care; secondary suite, minor home occupation, short-term rental
Smallest lot for a subdivision
1,400 m², 25 m wide
Lot coverage
50%; hard surfaces, buildings included, 60%
Height limit
Main buildings 24 m (6 storeys per the zone's purpose); accessory buildings 4.5 m
Setbacks
Front 3 m (9 m on Lakeshore Drive West); sides 4.5 m; rear 6 m (s. 10.5.2). Accessory buildings: the zone sets no separate yards for them, so they keep these (our reading); they stand behind the main building's front face, those of 10 m² or less anywhere behind it, and a structure joined to the main building by its foundation or roof counts as part of it (ss. 4.2.3, 4.2.4, 4.2.6). In a zone allowing more than two homes, underground parking and other structures wholly below ground may reach under required yards, covered for landscaping (s. 4.9.2). Outdoor pools and hot tubs: not in the required front yard; above-ground ones sited as accessory buildings; at-grade pools 1.0 m from side and rear lot lines and 3.0 m from any street (s. 4.7). Into required yards (Table 4.1, s. 4.9): chimneys, sills, cornices and cantilevers under a quarter of the wall 0.6 m; eaves and canopies 0.6 m into an interior side yard, 1.5 m into the front or exterior side and 3.0 m into the rear; open stairs, landings, ramps and patios, and balconies, porches and decks, 1.5 m into the front or exterior side and 3.0 m into the rear, none listed for an interior side (stairs, landings and patios under 0.6 m above grade not counted, wheelchair ramps unlimited); window wells 0.9 m; on accessory buildings and carriage houses eaves 0.6 m and canopies, stairs, patios, balconies, porches and decks none; a concrete stair down to a basement into any setback (s. 4.9.3). A garage or carport reached from the street, and a driveway gate over 1.2 m, stands 6 m from the curb or sidewalk (ss. 4.2.7, 4.2.8). Setbacks from a collector or arterial road are measured from its future line in the official community plan (s. 4.6.1). Nothing over 1.2 m in a corner visibility triangle (s. 4.3). No development within 30 m of a watercourse unless a Qualified Environmental Professional sets less (s. 4.14)

Floor area ratio (FAR) is net floor area divided by lot area (s. 3.2); land given up for a road still counts in it and in coverage (s. 4.6.4).

Hard surfaces (buildings, parking, driveways, walks and patios together) cover at most 60% of the lot (s. 10.5.4).

Amenity space: 10 m² per home, a quarter of it at ground level, and at most a fifth of it indoors (s. 10.5.3).

Higher densities on named lots (s. 10.5.5): 1.98 FAR on three on Churchill Avenue; 1.7 FAR on one on Yorkton Avenue, with a restaurant, office and shop of up to 375 m² together; 1.73 FAR on one on Eckhardt Avenue West; 1.7 FAR on one on Comox Street.

Site-specific uses on named lots (s. 10.5.5): an office on one on Winnipeg Street; parking on one on Wade Avenue; a private parking lot on two, on Westminster Avenue West and Burnaby Avenue.

Secondary suites (s. 8.1): one per home, inside it with its own door to the outside; needs a community sewer connection unless the lot is at least 830 m² and meets the provincial sewerage rules; never titled or strata-lotted apart from the home; 5 m² of private outdoor space; no parking space required (Table 6.6).

Minor home occupations (s. 7.3): an accessory use in the home, a suite, carriage house or accessory building; residents only; up to 25% of the home's floor area and 20 m²; one client visit and one commercial vehicle visit (8 am to 6 pm) a day; no outdoor storage or work, no change to the residential look of the land or buildings, and no nuisance from noise, vibration, smoke, dust, odour, heat, glare or electrical or radio interference; no retail sales of goods not made there, except goods incidental to the service, farm products, and mail, phone or internet sales the customer doesn't come in to see or pick up; a sign under the City's Sign Bylaw. Left out: repairing or painting vehicles, trailers or boats, tow trucks, manufacturing and industrial uses, escort services, cabinet making, welding and machine shops, a major care centre, meat cutting, commercial animal breeding, and parking or storing industrial or construction equipment or materials.

Short-term rental is a permitted use. The bylaw counts any stay of 90 days or less as short-term (s. 3.2), and requires a City business licence; only the property's principal resident may rent it out; at most two guests per bedroom and eight in all; no alterations that change the home's residential look; on a lot with a house and a secondary suite or carriage house, only one of the homes may be rented this way; the owner keeps renters from disturbing the neighbours with noise, light or traffic; a home occupation sign under the City's Sign Bylaw is allowed (ss. 3.2, 7.6). The bylaw also defines a high-occupancy short-term rental, for more than eight guests, and gives it parking of 1 space per licensed bedroom up to 4, the renters parking on the lot (s. 3.2, Table 6.6, s. 7.6.4), yet caps every short-term rental at eight guests (ss. 3.2, 7.6.3.2) and lists it in no zone, so whether one can be licensed is unclear; ask the City of Penticton.

Parking (Table 6.6): 1 space per house or duplex unit; 1 per apartment, townhouse or cluster home plus 0.2 for visitors; none for a secondary suite or carriage house; 0.5 per non-market home.

Parking may be paid for in cash instead, but not below one space per home (s. 6.1.2).

Transit-oriented areas (Schedules C to E, around the bus exchanges at Penticton Plaza, Peachtree Square and Cherry Lane Mall; Area 1 within 200 m, Area 2 200 to 400 m, s. 3.2): residential buildings, and mixed-use ones at least half residential, need no parking for homes and may reach 6 storeys and 2.5 FAR in Area 1 or 4 storeys and 1.5 FAR in Area 2, or the zone's own figures where higher; accessible spaces are still required by Table 6.8 (s. 4.16).

Accessory buildings go up only with or after the main building, stand behind its front face (those of 10 m² or less anywhere behind it), and can't be lived in except as a carriage house where allowed (ss. 4.2.1 to 4.2.4).

Fences and walls up to 1.2 m, or 1.8 m behind the front yard setback and in side and rear yards, or 2.4 m beside a controlled-access highway; nothing over 1.2 m in a corner visibility triangle; no barbed, electric or razor wire (ss. 4.3, 5.4.1). Retaining walls up to 1.2 m above approved grade in required yards and 2.4 m elsewhere; in a yard up to 2.4 m where the lot's natural grade is lower than the lot beside it; higher where approved as a condition of subdivision; parallel walls at least 1.2 m apart; a fence on a retaining wall is measured on its own (ss. 5.4.2, 5.4.3).

Landscape buffers, for commercial uses and for housing of 5 or more homes: 3 m wide beside R4-L and R4-S lots and along highways other than lanes, with a visual screen at least 1.2 m high beside residential zones (Table 5.1). Each buffer carries a tree for every 10 m (deciduous at least 60 mm caliper with 1.5 m of clear stem, conifers at least 2.5 m tall) and a shrub for every metre, runs unbroken but for walks and driveways, is watered by an automatic underground irrigation system, and may narrow to a building's actual setback where that is less (ss. 5.2.1 to 5.2.4). Multiple housing, commercial and industrial uses keep garbage and recycling bins on their own site, screened from neighbours and streets by landscaping or fencing 1.2 m to 2.0 m high, those a truck reaches with 3.0 m clear width and 4.6 m clear height, marked apart from parking and loading spaces and never on a public right-of-way (s. 4.10).

Living in an RV on a lot is limited to 10 days in any 30 (s. 4.8.2).

One recreational vehicle may be parked outside per home, more only inside a building, and no vehicle over 5,600 kg unless it is enclosed (s. 6.1.1).

Metal storage containers only during construction under a building permit (s. 4.8.4).

No development within 30 m of a watercourse, or the smaller distance a Qualified Environmental Professional sets under the Riparian Areas Protection Regulation and the official community plan's development permit areas (s. 4.14).

No building inside an existing or future collector or arterial road right-of-way shown in the official community plan; setbacks from those roads are measured from the future road line (s. 4.6).

Nothing, cranes included, may rise above the Horizontal Surface of the federal Penticton Airport Zoning Regulations without federal approval (s. 4.5).

Every zone also allows public parks, utility services, urban agriculture (growing food on part of a lot, by the owner or someone the owner lets), cultural exhibits and a minor day care (up to 8 children, at most 13 hours a day) (ss. 3.2, 4.12).

Chimneys, aerials and antennas, water towers, wind machines, monuments, observation and transmission towers, steeples, solar thermal collectors and flagpoles may reach twice the zone's height; elevator housings, roof stair entrances, ventilating equipment, skylights and the like covering up to 10% of the roof may exceed it if screened from view, and the screen may exceed fence heights; a sunken pedestrian entrance (up to 40% of the wall or 7 m²) or window well (0.9 m out, a quarter of the wall) isn't counted in height (ss. 4.2.2.1, 4.4). The airport surface limit still applies (s. 4.5).

For walls thicker than 0.165 m because of insulation or weather protection, the City may leave up to 0.305 m of the thickness out of floor area and lot coverage and cut setbacks by 0.25 m, and roof thickness over 0.3 m needed for the Step Code's Passive House or a similar standard may exceed the height limit (s. 4.15).

A temporary use in a tent, trailer, RV, manufactured home or other structure not fixed to the site isn't allowed, except one accessory to a campground, industrial or public use (s. 4.8.2.1); a zone's permitted use may run outdoors for a while and on its required parking (s. 4.8.3). A sales centre for units or lots under construction is allowed in every zone while sales go on, and builders' temporary buildings until 30 days after final inspection (ss. 1.6.2, 1.6.4).

A lot in two zones is treated as two lots, the zone line serving as the interior side lot line for each part (s. 2.7). A concrete outside staircase down to a basement may sit in any setback (s. 4.9.3).

Parking in general (Chapter 6): spaces on the same lot as the use, fractions rounded down, mixed uses added together, a use the table doesn't name rated like the nearest; shared spaces for uses busy at different times (s. 6.1.3); standard spaces 2.7 m by 5.8 m at 90 degrees, accessible ones 3.7 m wide, 0.3 m wider beside a wall or fence over 0.3 m high and 0.5 m wider alongside a lot line, 2.0 m clear overhead, and up to a quarter of them small-car spaces, all of them where no parking is required (ss. 6.1.1, 6.1.5); required spaces in tandem only for a single detached house, extra spaces may be tandem, visitor spaces never (s. 6.1.6); an area of five or more spaces marked out, drained to planting or a drainage system, hard-surfaced except in agricultural zones, parks and open space, with wheel stops where spaces meet sidewalks, buildings, streets or landscaping, and grades of 6% or less (s. 6.3.1); lights aimed down (s. 6.3.3); a lot with access to Highway 97 meets the Ministry of Transportation's parking and loading standards (s. 6.1.1.8).

Accessible spaces, counted in the required total and never reduced: none under 10 spaces, 1 for 10 to 20, 2 for 21 to 50, 3 for 51 to 100, then 3 plus 2% of the spaces over 100; near the entrance, as level as practicable, signed (s. 6.7, Table 6.8).

An outdoor parking or loading area of 10 or more spaces carries 2 m² of landscaped island per space (s. 6.3.2).

Each new home, a carriage house included, gets an energized outlet for Level 2 electric vehicle charging, except a new home made inside an existing building; half of any accessible spaces get one (s. 6.6, Table 6.7).

Multiple housing on a new building or addition provides bicycle parking: 0.5 secure spaces (lockers or locked rooms) and 0.1 rack spaces per home, no secure space for a home with its own garage; where bike parking is required, five extra bike spaces can cut the car parking by one space at most (ss. 6.1.2.1, 6.4, Table 6.4).

Required parking may instead be paid for: $13,000 a space into the City's parking and transportation reserves, $1,000 a secure bike space for commercial uses (s. 6.1.2.2, Table 6.1); in RM2 and RM3 never below one space per home.

Site-specific exceptions listed in the bylaw by legal description can add or change uses for one property, and development permit areas, the ALR and building rules apply on top. Confirm with the City of Penticton's planning department before you buy or build.

Source: City of Penticton Zoning Bylaw No. 2024-22 (summarised in our words, checked 2026-10-31); zone map: Open Government Licence – City of Penticton.

City of Penticton Zoning Bylaw No. 2024-22 applies in Penticton.

RM3 in other BC bylaws: what RM3 allows in each of the 7 we've summarised.

Other zones in this bylaw

FG Forestry and Grazing, A Agriculture, RC Country Residential Housing, R4-L Small-Scale Multi-Unit Residential: Large Lot, R4-S Small-Scale Multi-Unit Residential: Small Lot, RM1 Bareland Strata Housing, RM2 Low Density Multiple Housing, RM4 High Density Multiple Housing, RM5 Urban Residential, RSM Manufactured Home Park Housing, C1 Commercial Transition, C2 Neighbourhood Commercial, C3 Mixed Use Commercial, C4 General Commercial, C5 Urban Centre Commercial, C6 Urban Peripheral Commercial, C7 Service Commercial, C8 Vehicle Service Station, C9 Marina Way Commercial, CT1 Tourist Commercial, CT2 Campground Commercial, CT3 Hotel Resort, M1 General Industrial, M2 Heavy Industrial, M3 Wrecking Yard, P1 Public Assembly, P2 Parks and Recreation, P3 Major Utilities, P4 Environmental Reserve, CD2 Comprehensive Development (270 Riverside Drive), CD3 Comprehensive Development (2784 Skaha Lake Road), CD5 Comprehensive Development (3388 Skaha Lake Road), CD6 Comprehensive Development (962 Churchill Avenue), CD7 Comprehensive Development (154 Brunswick Street), CD8 Comprehensive Development (795 Westminster Ave W), CD9 Comprehensive Development (1704 Government Street), CD10 Comprehensive Development (955 Timmins Street), CD11 Comprehensive Development (10 Galt Avenue).