PlaceDossier / Zoning / City of Merritt

P3: Post-Secondary Educational

P3 is a zone in City of Merritt Zoning Bylaw No. 2284, 2020 (City of Merritt). Our summary of Section 7.25 of the bylaw as amended to January 13, 2026.

What the zone allows

Homes allowed
Apartments and townhouses for faculty and students, up to 90 per hectare; no limit for homes lived in by current students
Main uses
College or university; daycare, apartments and townhouses, restaurant, pub, convenience store, urban agriculture
Smallest lot for a subdivision
450 m², 15 m wide, 30 m deep
Lot coverage
75%
Height limit
18 m or 4 storeys; homes 22 m or 5 storeys
Setbacks
Front 0 m, interior sides 3 m, exterior side 0 m, rear 3 m, apartments the same (Table 7.25.5). Accessory buildings: front the main building's front line, interior sides 1.2 m, exterior side 0 m, rear 1.2 m (Table 7.25.5); 1.5 m between an accessory building and other structures, 3 m between a shipping container and combustible structures (s. 7.25.5(d)). Storage containers in the rear yard, 3.0 m from combustible structures, doors facing away from the main building's entrances and windows, screened (s. 4.19.3). A hen enclosure behind the main building, 1.2 m from any parcel line and out of sight of the street (s. 4.39.3). Accessory buildings keep the main building's front setback (s. 4.16.4); a screened shed or bike locker up to 1.25 m high and 3 m² may come to 1.2 m from the front line (ss. 4.16.5, 6.2.3(c)). Table 4.11 also lets accessory buildings reach 4.8 m into the front setback, keeping 1.2 m from the front line in residential zones, so how far forward a bigger shed may go is unclear. Pools keep the main building's front setback and 1.2 m from side and rear lines; above-ground pools and decks over 0.6 m high sited as accessory buildings (s. 4.17). Temporary structures, fabric ones included (one per parcel), meet the accessory building setbacks (s. 4.18). Into a setback (Table 4.11): chimneys, sills, bay windows, parapets and small cantilevers 0.6 m; eaves and roofs 0.6 m on an interior side, 1.5 m front, exterior side or rear; canopies and awnings 0.6 m interior side, 1.5 m front or exterior side, 3.0 m rear; balconies, porches, decks, patios and verandas 1.5 m front or exterior side, 3.0 m rear (not counted under 0.6 m above grade; no foundation may project); open stairs, landings and ramps 1.5 m front or exterior side; wheelchair ramps, basement stairs, fences, retaining walls, signs, poles, air conditioners and freestanding solar no limit; underground structures no limit if they rise no more than 0.5 m above average grade (s. 4.11). Nothing over 1.25 m above the street's grade in the 6 m sight triangle at a corner (s. 4.15). On a corner parcel the front line is the shortest line along a road other than a lane (s. 2.2, front parcel line); setbacks from a panhandle parcel's access strip are 0 m (s. 4.9.4); siting exceptions along arterial highways are subject to the Ministry of Transportation and Infrastructure (s. 4.11.1). Setbacks from a watercourse's natural boundary follow provincial and federal rules (s. 4.24); fill under a floodplain floor stays 30 m from the natural boundary of the Nicola, the Coldwater or another watercourse unless a riparian assessment allows it (s. 4.30.2). Refuse and recycling bins 1.2 m from an abutting residential zone (s. 6.3.3)

Coverage can rise to 90% with permeable driveways or paths on 15% of the lot.

Homes sit above or below the main floor or behind other uses, with their own entrance (s. 7.25.6).

Backyard hens are allowed (s. 4.39).

The bylaw doesn't allow short-term rental (stays under 30 days) in this zone (s. 4.34.1).

An accessory building can't be a home, a suite or a short-term rental (s. 4.16), and goes up only with or after the main building.

Fences up to 1.25 m between the street and the front of the building, 2.5 m elsewhere; a 6 m sight triangle at a corner stays clear above 1.25 m (ss. 4.14, 4.15).

On a lot averaging a 15% slope or more, buildings rise no higher than 7 m above the street centreline's level at the middle of the lot (lots below the street) or above the middle of the rear lot line (lots above it), and no wall rises more than 9 m from the lowest finished grade (s. 4.21).

Minimum lot sizes apply to new lots; an existing smaller lot stays lawful (s. 4.6).

Every zone also allows public utilities, electric vehicle charging, and temporary site buildings and containers during construction (s. 4.2).

Floodplain (s. 4.30, Schedule B): land below the Province's 200-year flood level of the Nicola and Coldwater rivers, or less than 1.5 m above any other watercourse, is floodplain. Floors of homes, businesses and storage there sit at least 0.6 m above that level, and fill stays 30 m from the rivers and other watercourses unless a riparian assessment allows it. Setbacks from streams follow provincial and federal rules (s. 4.24).

Site-specific exceptions listed in the bylaw by legal description can add or change uses for one property, and development permit areas, the ALR and building rules apply on top. Confirm with the City of Merritt's planning department before you buy or build.

Source: City of Merritt Zoning Bylaw No. 2284, 2020 (summarised in our words, checked 2026-10-29); zone map: Open Government Licence – Thompson-Nicola Regional District.

City of Merritt Zoning Bylaw No. 2284, 2020 applies in Merritt.

P-3 in other BC bylaws: what P-3 allows in each of the 16 we've summarised.

Other zones in this bylaw

AR1 Agricultural, R1 Low Density Residential, R2 Residential Mobile Home, R3 Small Parcel Residential, R4 Residential Modular Home, R5 Mobile Home Park, R7 Medium Density Residential, R8 High Density Residential, RC1 Residential Care Housing, C1 Recreational Commercial, C2 Tourist Commercial, C3 Regional Commercial, C4 Corridor Commercial, C5 Neighbourhood Commercial, C6 City Centre District, C7 Service Commercial, C8 Airport Commercial, M1 Light Industrial, M2 Heavy Industrial, P1 Park and Cemetery, P2 Institutional and Public Use, FD Future Development, CD01-RC Comprehensive Development – Residential Commercial, CD2-RC Comprehensive Development – Gateway 286, CD3-GW Comprehensive Development – Gateway 286.