PlaceDossier / Zoning / Columbia Shuswap Regional District
GC: General Commercial
GC is a zone in Magna Bay Zoning Bylaw No. 800 (Columbia Shuswap Regional District). Our summary of Section 5.7 of the bylaw as amended to October 8, 2026.
What the zone allows
- Homes allowed
- One dwelling for the owner, operator or caretaker of the business
- Main uses
- Campground, motel and restaurant on lots of 1 ha or more; marina (no fuel sales), nursery, office, retail store
- Smallest lot for a subdivision
- 1 ha (30 m wide)
- Lot coverage
- 40%
- Height limit
- Main buildings 11.5 m, accessory buildings 10 m
- Setbacks
- Front 4.5 m, interior side 2.5 m, exterior side 4.5 m, rear 3 m
Campgrounds hold up to 5 camping spaces per hectare (s. 3.12). Outdoor storage and display stay within the setbacks. A loading space stays out of the front setback and at least 7.5 m from the nearest point of a road intersection (s. 4.6(2)).
One part of Section 17 (s. 5.7(3)) also allows a service station and a laundromat, and a campground there up to 10.5 spaces per hectare.
Floodplain (ss. 3.4 to 3.6): no buildings within 15 m of Shuswap Lake's mean annual high water mark (348.3 m), 30 m of Ross Creek, 20 m of Onyx Creek or 15 m of other water; floors used for living or for goods floodwater could damage sit above 351 m on the lake, 2 m above Onyx Creek and 1.5 m above other water. Garages, small additions, docks and accessory buildings with no living space are exempt from parts of this, and so are farm buildings other than closed-sided livestock housing; a farm house on an ALR lot of 8.1 ha or more needs its floor only 1 m above the ground or at the flood level, whichever is lower (s. 3.6(6)); and the CSRD asks for a surveyor's certificate.
Nothing closer than 4.5 m to a provincial highway right of way without a Ministry of Transportation permit (s. 3.2(l)). On a corner, no fence, plant or structure over 0.6 m within the sight triangle, 6 m back from the intersection (s. 3.2(j), (k)).
Allowed in a setback (s. 3.2): wheelchair ramps, utility and lighting poles and anything below finished ground; steps, signs and landscaping such as a trellis or pond no closer than 1 m to a side line; eaves and gutters no closer than 1 m to any line; hot tubs and uncovered pools not between the main building and the front line and, our reading of a run-together clause, no closer than 2 m to other lines; fences up to 2.4 m and retaining walls up to 1.5 m outside the sight triangle; stepped landscape walls at least 1.5 m apart, but not beside a section 42 road under the Transportation Act or in the sight triangle. A bare land strata's access route counts as a road for setbacks (s. 3.9).
Chimneys, flag poles, area lighting poles and community water tanks may go up to 20% over the height limit; antennas, telephone, power and cable poles and farm buildings such as barns, grain storage and silos have no limit (s. 3.1).
Site-specific exceptions listed in the bylaw by legal description can add or change uses for one property, and development permit areas, the ALR and building rules apply on top. Confirm with the CSRD's planning department before you buy or build.
Source: Magna Bay Zoning Bylaw No. 800 (summarised in our words, checked 2026-10-30); zone map: Open Government Licence – Columbia Shuswap Regional District.
Magna Bay Zoning Bylaw No. 800 applies in Columbia-Shuswap, Electoral Area F.
GC in other BC bylaws: what GC allows in each of the 4 we've summarised.
Other zones in this bylaw
A Agriculture, R Rural, CR Country Residential, RS Residential, MSR Multi-Single Family Residential, IG Industrial Gravel Processing, P Institutional, CD-1 Comprehensive Development 1, CDF-2 Comprehensive Development 2.