PlaceDossier / Zoning / Regional District of East Kootenay
P-4: Public Works and Utility
P-4 is a zone in Electoral Area E Zoning and Floodplain Management Bylaw No. 2502, 2014 (Regional District of East Kootenay). Our summary of Section 4.28 of the bylaw as amended to August 14, 2026.
What the zone allows
- Homes allowed
- None: the zone lists no dwelling
- Main uses
- Cemetery and crematorium, public works and storage yards, landfill with recycling depot, waste transfer station, public utilities, airport and heliport, government services, farming, wireless towers
- Smallest lot for a subdivision
- None set in the zone
- Height limit
- 10 m
- Setbacks
- Front 7.5 m, rear and sides 6 m. Farm buildings (s. 1.20(4)): dairy, livestock, fur farm and poultry buildings 15 m from lot lines (confined livestock areas 30 m) and 30 m from a well or spring; mushroom barns 7.5 m; buildings with boilers or fan walls 15 m; other farm buildings 4.5 m; livestock and poultry barns, stables, milking buildings, mushroom barns and confined livestock areas 15 m from the high water mark of a lake or watercourse (30 m for confined livestock areas of more than 10 animal units); manure storage 30 m from a well or spring and 15 m from a lake or watercourse. Into a setback: steps 1.2 m (not fire escapes); eaves, gutters, cornices, sills, bay windows and chimneys half the setback, at most 1 m into a front or rear one; sundecks, balconies, marquees and canopies half the setback, at most 1.8 m into a front or rear one. Awning-covered patios, landscape features, hitches, poles, antennas, dishes, utility works, underground structures and solar apparatus may sit in a setback; fences, screens, paved surfaces, retaining walls and signs aren't held to the zone's setbacks (s. 1.10(3), (4)). A swimming pool may sit in a required yard but 3 m from the front and rear lot lines (s. 1.10(3)); how near one may come to a side line isn't said, so unclear. A boathouse needs no rear setback (s. 1.10(3)); it is one storey, no taller than the zone's accessory buildings, with no deck above it and no sleeping or sanitary rooms (s. 1.09(4)). On a corner lot nothing that blocks the view, buildings and fences included, in the triangle reaching 6 m along each lot line from the corner (s. 1.12). 22 m from a lot line on a controlled access highway unless a frontage road serves the lot (s. 1.06). An accessory dwelling keeps the main use's setbacks (s. 1.10(5)). Cannabis production buildings, where allowed, 15 m from the front and inside side lines and 30 m from the rear and a side on a road (s. 1.10(6)). Fill holding up a floor above the flood level may not reach into the floodplain setback: 30 m from the high water mark of the Kootenay and Lussier rivers, Skookumchuck Creek, the St. Mary River and Perry Creek, 15 m from other watercourses and 7.5 m from a lake, marsh or pond (Schedule B, ss. 1.02(2), 2.01(1)(b)); the bylaw doesn't say the same of a building on posts or piers, so whether one may stand there is unclear. No side setback along a common wall; setbacks from a common access lot are measured as from a road; a lot in two zones is sited as two lots (s. 3.2(2), (3), (5))
The zone sets no lot coverage.
Fences or screens at least 2 m tall (s. 1.15).
Farm buildings have no height limit (s. 1.11(4)); their setbacks (s. 1.20(4)) are listed with the zone's setbacks.
Heights are measured from finished grade to halfway between the eaves and the ridge; a flat roof to its top; the walls under a single-pitch roof may reach 1.5 m above the limit (ss. 3.2(6), 1.11(6)).
Every zone also allows parks, public utilities, highways and railways, heritage sites and conservation areas (s. 1.03). Buildings stay 22 m from a controlled access highway unless the lot is on a frontage road (s. 1.06).
Inside the ALR, farm uses and those the Agricultural Land Commission approves are permitted, as is cannabis production under the ALR Use Regulation; the Commission's rules also apply to suites, farm-hand dwellings and dwellings for a relative needing care (ss. 1.14, 1.20, 1.21, 1.25, 1.27).
Floodplain (Schedule B): the floor of any living or business space sits above 772 m (geodetic) beside Wasa Lake, at least 3 m above the high water mark of the Kootenay and Lussier rivers, Skookumchuck Creek, the St. Mary River and Perry Creek, and 1.5 m above any other stream, lake, marsh or pond (on the Lussier River fan mapped in Schedule B1, the highest of 1 m above the ground, 0.6 m above anything that could pond water, or an engineer's level); fill holding up a floor stays 30 m from those five rivers and creeks, 15 m from other streams and 7.5 m from any lake, marsh or pond. On the Argyle Creek hazard area (Schedule B2) the setbacks apply and an engineer assesses the site (Schedule B, Part 3).
Site-specific exceptions listed in the bylaw by legal description can add or change uses for one property, and development permit areas, the ALR and building rules apply on top. Confirm with the RDEK's planning department before you buy or build.
Source: Electoral Area E Zoning and Floodplain Management Bylaw No. 2502, 2014 (summarised in our words, checked 2026-10-29); zone map: Open Government Licence – Regional District of East Kootenay.
Electoral Area E Zoning and Floodplain Management Bylaw No. 2502, 2014 applies in East Kootenay, Electoral Area E, East Kootenay, Electoral Area C.
P-4 in other BC bylaws: what P-4 allows in each of the 8 we've summarised.
Other zones in this bylaw
R-1 Residential, R-1(A) Residential (A), RS-1 Residential (Semi-Rural), RS-4 Residential (Semi-Rural), R-MP Manufactured Home Park Residential, RR-1 Rural Residential (Estate), RR-2 Rural Residential (Small Holding), RR-4 Rural Residential (Hobby Farm), RR-8 Rural Residential (Country), RR-16 Rural Residential (Extensive), RR-60 Rural Resource, RES-1(A) Recreation Residential (A), RES-1(B) Recreation Residential (B), RES-1(C) Recreation Residential (C), C-1 Highway Commercial, C-2 Local Commercial, C-3 General Commercial, C-4 Service Commercial, C-5 Recreation Commercial, C-6 Golf Course Commercial, C-7 Tourist Commercial, I-1 Industrial, P-1 Public Institutional, P-2 Parks and Open Space, P-3 Parks and Open Space (Campground), WP-1 Watershed Protection.