RES-2: Resort Recreation
RES-2 is a zone in South Country Zoning & Floodplain Management Bylaw No. 2320, 2011 (Regional District of East Kootenay). Our summary of Section 4.13(A) of the bylaw as amended to February 13, 2026.
What the zone allows
- Homes allowed
- One dwelling, accessory to the campground (the zone; s. 1.18(3))
- Main uses
- Campground; general store and restaurant (each up to 120 m²), sani-dump, gas station, boat rental, sales and repair, launching ramp
- Smallest lot for a subdivision
- 4 ha
- Lot coverage
- 70%
- Height limit
- 9 m
- Setbacks
- All buildings: front 7.5 m, rear and sides 4.5 m. Gas pumps and pump islands 4.5 m from every lot line (s. 1.10(3)). Loading spaces 7.5 m from the nearest point where two roads meet (Schedule A, s. 3.5(2)). Into a setback: steps 1.2 m (not fire escapes); eaves, gutters, cornices, sills, bay windows and chimneys half the setback, at most 1 m into a front or rear one; sundecks, balconies, marquees and canopies half the setback, at most 1.8 m into a front or rear one. Awning-covered patios, landscape features, hitches, poles, antennas, dishes, utility works, underground structures and solar apparatus may also project into a setback; fences, screens, paved surfaces, retaining walls and signs aren't held to the zone's setbacks (s. 1.10(3), (4)). A swimming pool may sit in a required yard but 3 m from the front and rear lot lines (s. 1.10(3)); how near one may come to a side line isn't said, so unclear. On a corner lot nothing that blocks the view, buildings and fences included, in the triangle reaching 6 m along each lot line from the corner (s. 1.12). 22 m from a lot line on a controlled access highway unless a frontage road serves the lot (s. 1.6). An accessory dwelling keeps the main use's setbacks (s. 1.10(5)); RVs keep the zone's setbacks for accessory buildings (s. 1.19(2)). Cannabis production buildings, where allowed (the zone, or ALR land under s. 1.27), 15 m from the front and inside side lines and 30 m from the rear and a side on a road (s. 1.10(6)). Fill that holds up a floor or pad stays out of the floodplain setbacks, 15 m from a watercourse and 7.5 m from a lake, marsh or pond other than the reservoir (the rule limits fill, not supports), and buildings with living space or goods that flood water would damage stay upland of the reservoir's 750.11 m contour (Schedule B, ss. 1.2(2), 2.1(1)(b)). No side setback along a common wall; setbacks from a common access lot are measured as from a road; a lot in two zones is sited as two lots, each building in its own zone (s. 3.2(2), (3), (5))
Campgrounds follow the RDEK's Campground Bylaw No. 2403, which also lists what may go with them (s. 1.16).
Outdoor storage is screened by a solid board fence or evergreen hedge at least 2 m tall on every side not facing a building on the lot; fences up to 2 m along a lot line next to a residential or institutional zone or a lot with a home (s. 1.15).
New lots also need at least 1,670 m² of usable land: one piece averaging 15% slope or less, with no land slip, avalanche, rock fall, flooding or high water table hazard, and above 750.11 m in elevation (ss. 2.2, 3.3).
Heights are measured from finished grade to halfway between the eaves and the ridge; a flat roof to its top; the walls under a single-pitch roof may reach 1.5 m above the limit (ss. 3.2(6), 1.11(6)).
Every zone also allows parks, public utilities, highways and railways, surface parking, heritage sites and conservation areas (s. 1.3). Buildings stay 22 m from a controlled access highway unless the lot is on a frontage road (s. 1.6).
Inside the ALR, farm uses and those the Agricultural Land Commission approves are permitted, as is cannabis production under the ALR Use Regulation, and farm buildings there keep the farm setbacks of s. 1.20(4); the Commission's rules also apply to suites, farm-hand dwellings and dwellings for a relative needing care (ss. 1.14, 1.20, 1.21, 1.25, 1.27).
Floodplain (Schedule B): the floor of any living or business space sits above 751 m beside Lake Koocanusa, and 1.5 m above the high water mark of any other stream, lake, marsh or pond (in a Special Policy Area, such as an alluvial fan, the highest of 1 m above the ground, 0.6 m above anything that could pond water, or an engineer's level); no basement floor below 751 m; buildings with living space or goods that flood water would damage stay upland of the 750.11 m contour of the reservoir; fill that holds up a floor or pad stays 15 m from streams and 7.5 m from any other lake, marsh or pond (supports aren't held back).
Site-specific exceptions listed in the bylaw by legal description can add or change uses for one property, and development permit areas, the ALR and building rules apply on top. Confirm with the RDEK's planning department before you buy or build.
Source: South Country Zoning & Floodplain Management Bylaw No. 2320, 2011 (summarised in our words, checked 2026-10-29); zone map: Open Government Licence – Regional District of East Kootenay.
South Country Zoning & Floodplain Management Bylaw No. 2320, 2011 applies in East Kootenay, Electoral Area B.
RES-2 in other BC bylaws: what RES-2 allows in each of the 3 we've summarised.
Other zones in this bylaw
RS-1 Residential (Semi-Rural), RS-1(A) Residential (Semi-Rural Single Family), RS-4 Residential (Acreage), RR-1 Rural Residential (Estate), RR-2 Rural Residential (Small Holding), RR-4 Rural Residential (Hobby Farm), RR-8 Rural Residential (Country), RR-16 Rural Residential (Extensive), RR-60 Rural Resource, I-1 Light Industrial, C-1 Local Commercial, RES-1 Recreation Commercial, M-2 Marine General, P-1 Public Institutional, P-2 Parks and Open Space, P-3 Public Works and Utility.