PlaceDossier / Zoning / Regional District of East Kootenay

M-1: Marine – Restricted

M-1 is a zone in SweetWater Zoning & Floodplain Management Bylaw No. 2127, 2009 (Regional District of East Kootenay). Our summary of Section 4.08 of the bylaw as amended to June 12, 2026.

What the zone allows

Homes allowed
None: the zone lists no dwelling
Main uses
Parks and open space, lighthouse, observation tower
Smallest lot for a subdivision
None set in the zone
Height limit
None set in the zone
Setbacks
None set in the zone

No walkway, boardwalk or other structure may reach below the lake's normal full pool level of 749.50 m, and no mooring buoys (ss. 4.08(3), 3.03).

The zone sets no lot size, coverage, height or setbacks.

No outdoor storage (allowed only in the C-1 and M-2 zones; s. 1.16(4)).

The bylaw sets no fence height for this zone; no barbed wire or electric fencing (s. 1.16).

An RV or park model trailer can't be used as a home (s. 1.05), and an RV may be placed and lived in only in a zone that allows campgrounds (RES-1) or while a home is being built (s. 1.20).

Lot lines and setbacks (ss. 3.02, 3.03; s. 1.10(2)): a setback is measured from a building's outside wall to a lot line or, in the bylaw's words, a common lot access. The front lot line is the line on a road, the shortest one where more than one meets a road, the one most neighbouring buildings face where front and back both meet a road, or for a panhandle lot the line nearest the road it's reached from, not counting the access strip; a lot reached through a common lot is measured as if the common lot were a road. A strata access route is strata common property rather than a road (highway), and the bylaw's road also leaves out a common lot access route (our reading), so which setback a side or rear line beside an access route takes, where the zone doesn't say, is unclear; ask the RDEK. Side setbacks don't apply along a common wall; a lot under two zones is set back as two lots, every building inside its own zone; an accessory building attached to the main building counts as part of it.

Into setbacks (s. 1.11(2), (3), (5)): steps may reach 1.2 m (fire escapes aside); eaves, gutters, cornices, sills, bay windows and chimneys half the setback, at most 1 m into a front or rear setback; sundecks, balconies, marquees and canopies half the setback, at most 1.8 m into a front or rear one (the side setbacks have the half limit only, our reading); cantilevers may not project. A swimming pool stays 3 m from the front and rear lot lines. Open or awning-covered patios, landscape features, poles, antennas, dishes, utilities, solar equipment and structures wholly under the finished ground (vents and fill pipes aside) may sit in setbacks, and the zone's siting rules don't apply to fences, screens, paved surfaces, retaining walls and signs.

On a corner lot, nothing (buildings, structures, fences and screens included) may block the view in the triangle 6 m along each lot line from the corner where they meet the road (ss. 1.11(3), 1.13).

A new lot needs both a community water system and a community sewer system, unless it is for a park, public utility, solid waste facility, parking lot or access route (s. 2.01(3), (4)). In a bare land strata, the zone's minimum lot size is the minimum average lot size (s. 2.01(A)).

Heights are measured from finished grade to halfway between the eaves and the ridge of the main roof (s. 3.03); chimneys, antennas, solar collectors, spires and the like are exempt (s. 1.12(2)).

Every zone also allows parks, public utilities, highways and strata access routes, heritage and archaeological sites, and conservation, recreation and ecological reserves (s. 1.04). Salvage yards and third-party advertising are banned everywhere, and intensive agriculture outside the ALR (s. 1.05). Buildings stay 22 m from a controlled access highway unless the lot is on a frontage road (s. 1.07).

Floodplain (Schedule B): the underside of the floor of any space for living, business or goods that flood water would damage sits above 751.0 m beside Lake Koocanusa, and 1.5 m above the high water mark of any other watercourse; such buildings stay upland of the 750.11 m contour of the reservoir; fill holding up a floor stays 10 m from the lake's natural boundary (mapped on Schedule B1) and 15 m from the high water mark of other watercourses (Schedule B, ss. 1.02(2), 2.01(1)(b)). The lake's natural boundary is its stable top of bank (or the predicted one where the bank will erode, the top of fill, or 10 m back from the 749.50 m full pool line where the shore is flat) (s. 3.03). The flood construction level (not the setbacks) doesn't bind renovations without an addition, an addition under 25% of the floor area at the old floor level that doesn't worsen a setback (unless such an exemption was granted before), carports, garages and entrance foyers, site amenities such as gazebos and trails, identification features, flagpoles, banners and navigation lights, marina gangways and equipment, or hot water tanks and furnaces behind a standard dyke (Schedule B2); the RDEK can relax a level or setback for one site on application (Schedule B, s. 3.02).

Basements are allowed only upland of the basement suitability line on Schedule B1, with the underside of the floor no lower than 751.0 m (Schedule B, s. 1.02(3)); the bylaw's definition of a basement also says none below the basement suitability elevation of 753.5 m (s. 3.03). How the two levels fit together is unclear, so ask the RDEK.

Geotechnical hazard (Schedule C, mapped on Schedule C1): on land rated Zone B, a subdivision or building permit needs a qualified professional's report that the land is safe for the use; on Zone C, no habitable buildings.

Site-specific exceptions listed in the bylaw by legal description can add or change uses for one property, and development permit areas, the ALR and building rules apply on top. Confirm with the RDEK's planning department before you buy or build.

Source: SweetWater Zoning & Floodplain Management Bylaw No. 2127, 2009 (summarised in our words, checked 2026-10-29); zone map: Open Government Licence – Regional District of East Kootenay.

SweetWater Zoning & Floodplain Management Bylaw No. 2127, 2009 applies in East Kootenay, Electoral Area B.

M1 in other BC bylaws: what M1 allows in each of the 14 we've summarised.

Other zones in this bylaw

R-1(A) Single Family Residential – Large Lot, R-1(B) Single Family Residential – Medium Lot, R-1(C) Single Family Residential – Small Lot, R-3 Multiple Family Residential – Medium Density, C-1 Mixed Use Village Commercial, M-2 Marine – General, RES-1 Recreation Accommodation, P-2 Parks and Open Space, P-3 Works and Utility.