PlaceDossier / Zoning / Municipality of North Cowichan

PU: Public Use

PU is a zone in Zoning Bylaw 1997, No. 2950 (Municipality of North Cowichan). Our summary of Section 79 of the bylaw as amended to September 14, 2026.

What the zone allows

Homes allowed
None: the zone lists no home (s. 79(1))
Main uses
Public use (a building, facility or open space run by the federal or provincial government, a regional district or a municipality: utilities, a recycling drop-off depot, offices, a hospital, a prison, a university or college, or a Crown corporation, with an accessory helicopter pad), a child care centre, a food truck, trailer or cart (s. 79(1); definition in s. 12)
Smallest lot for a subdivision
No minimum set in the zone
Lot coverage
No limit set in the zone
Height limit
None set in the zone
Setbacks
None, except 8.0 m at a side or rear next to residentially zoned land and an 8.0 m front yard on an arterial highway (s. 79(2))

Land zoned PU is held by governments for public buildings, parks and utilities, so a lot here is rarely for sale; ask the Municipality what a lot here may be used for before you buy.

Short-term rental isn't a use this zone lists, and with no homes allowed there is none to rent (our reading).

Allowed in every zone: accessory buildings, civic use (schools, fire halls, parks and recreation facilities a public body owns, and sewage and water pumping stations and reservoirs of the Municipality or the regional district), public utility use the Municipality approves, and a licensed community care facility for a day care of up to 8 people or a residence for up to 10, no more than 6 of them in care (s. 48(1)-(3), (5); definitions in s. 12). An accessory use stays on the same lot as the main use (s. 42); a use the zone doesn't name isn't allowed (s. 5). A private aircraft landing strip, helicopter pad or aerodrome needs Council's prior approval (s. 41).

How the bylaw measures (s. 12): height runs from grade (the average finished ground level around the building) to the highest point, averaged over the building's outermost corners, leaving out church steeples, towers on safety buildings and silos; lot coverage counts the footprint of every building and structure, and of decks 150 mm or more above grade; a corner lot's front lot line is its shortest line along a street.

Parking for the uses the table names (s. 21(2)): a hospital 1.5 spaces per 3 bed spaces, a child care centre 1.5 per classroom plus 2 for short stays; it lists no rate for other public uses, so ask the Municipality. A common area for garbage, recycling and composting containers, walled or fenced for screening, in a convenient place on the same lot (s. 29(1)).

Required yards stay clear of buildings and structures except permitted projections (s. 33(1)); a building or part wholly below ground needs no side or rear setback (s. 33(2)). Up to 0.6 m into any required yard: steps, eaves, awnings, canopies, an open cantilevered balcony without a roof, porches, chimneys, cornices, gutters, pilasters, sills and a bay window with no habitable floor area (s. 35(1)). Into the front yard: a step to the main entrance, an accessibility ramp, and a deck, canopy, awning, porch or balcony up to 2.0 m (s. 35(2)); no upper-storey deck, porch or balcony projection in the front yard of a panhandle lot (s. 35(4)); a projection built to hold furniture must meet every yard requirement (s. 35(6)). An accessory building stays at least 1.22 m from the main building, eave to eave (s. 16).

Nothing over 1.1 m high may block the view at a street corner, inside a triangle 6 m along each street line from the corner (s. 36).

No fence height limit in this zone (s. 37.1(8)). A retaining wall in a yard follows the fence limit and no retaining wall anywhere is over 2 m, unless a grading plan accepted at subdivision allows it; a wall sits wholly on its lot and out of rights of way, easements and covenants without the holder's written permission (s. 37.2(1), (2), (12)).

One shipping container per lot may serve as an emergency preparedness kiosk, and a container may hold tools and materials while a building permit is active, removed before the occupancy permit (s. 40.1(e), (f)).

Where the lot is in a flood area, the underside of a floor in a building used for living, business or storing goods water can damage must not be below the flood construction level: the level on the bylaw's flood construction level map for the lower Cowichan River and Somenos or on the floodplain map for the Chemainus River or, where applicable, 3.0 m above the natural boundary of the Chemainus and Cowichan Rivers, elevation 27.4 m around Quamichan Lake, 1.5 m above the natural boundary of the sea, a lake, a watercourse, an intermittent pond or a swamp in the flood hazard area, or 0.6 m above the 200-year flood level an engineer sets (s. 14). Not for an addition to a home under 25% of the floor area it had when the bylaw was adopted, nor a carport, garage, storage, utility or workshop part (s. 15(2)); main electrical switchgear above that level, and cut-off switches on circuits into flooding areas (s. 15(1)).

Despite the zone's own rules, no building, structure or fill within 7.5 m of the sea's natural boundary or 15 m of any other watercourse or water source (wells aside), nor in a streamside assessment area unless the Riparian Areas Regulation is met (s. 13(1)); not for water-oriented loading in I2, portable sawmills or other water lot uses (s. 15(1)). A swimming pool at least 1.5 m from every lot line (s. 34), enclosed in a structure or by a fence 1.5 m to 1.8 m high built so it can't be climbed, any gate on hinges with a lock and opening freely only from the inside (s. 38); no generator, heat pump or air conditioner within 4.5 m of a lot line (s. 35(5)).

Site-specific exceptions listed in the bylaw by legal description can add or change uses for one property, and development permit areas, the ALR and building rules apply on top. Confirm with North Cowichan's planning department before you buy or build.

Source: Section 79 of Zoning Bylaw 1997, No. 2950 (summarised in our words, checked 2026-11-14); zone map: Open Government Licence – Municipality of North Cowichan.

Zoning Bylaw 1997, No. 2950 applies in North Cowichan.

Other residential, townhouse, apartment, rural and agricultural zones, the Commercial General zone C2, the Commercial Service zone C3, the Industrial Light and Heavy zones I1 and I2, the Public Use zone PU and the Comprehensive Development zones CD1, CD4 and CD18 zones in this bylaw

R3 Residential One and Two-Family, R1 Residential Rural, A2 Rural, R2 Residential Restricted, A3 Rural Restricted, A1 Agricultural, R1-U Urban Residential Rural, A4 Rural Resources, C2 Commercial General, CD4 Comprehensive Development Zone - Mixed Family, CD18 Kingsview Comprehensive Development Zone, R1-BM Bell McKinnon Residential Rural, R3-S Residential Small Lot Single-Family, R6 Residential Townhouse, A5 Rural Residential, C3 Commercial Service, I1 Industrial Light, R4 Residential Small Lot Mobile Home, R3-R Rural Residential One and Two-Family, R8 Residential Multi-Family Apartment, I2 Industrial Heavy, CD1 The Cliffs Comprehensive Development Zone.