What the zone allows

Homes allowed
As R2, with every home purpose-built rental housing. Townhouses and rowhouses up to 4 storeys, with no number of homes set (one secondary suite allowed in each townhouse); and whatever the R1 district allows (s. 1.2.2). Whether R1's limits on homes, coverage and height also bind small-scale housing built here is unclear: ask the City
Main uses
The R1 district's uses, townhouses, congregate housing, dormitories, an emergency shelter, live-work units, supportive and transitional housing; Shops, restaurants and personal and business services, a child care facility (up to 25 children), a community garden, energy generation, an active mobility hub and mobile vendors, only alongside a principal use, under the C1 district's conditions: one storey above ground, at most 250 m² a unit, child care excepted (a corner unit isn't limited to shops, restaurants and services); boarders, home-based child care, home occupations, secondary suites, short-term rental, accessory buildings (ss. 1.2.2, 1.2.3)
Smallest lot for a subdivision
None set in the district; subdivision goes to the City's Approving Officer (our reading)
Lot coverage
None set in the district; at least 30% of the lot left permeable, shown on a landscape architect's plan (Part 4-4.3)
Height limit
4 storeys (s. 1.2.4); storeys are counted through the part of the building with the most of them (Part 4-2.2)
Setbacks
Street 3.0 m, lane 1.2 m, sides 1.2 m, rear 3.0 m (s. 1.2.4). Between principal buildings 6.0 m face to face, 4.5 m corner to corner up to 4 storeys, none where they share a party wall; detached accessory buildings 2.4 m from other buildings (Part 4-1.2)

R2r is the same district with every home restricted to purpose-built rental housing: a building held in one ownership, not stratified, rented only (Part 3, Part 2).

The district sets no floor area ratio or homes per hectare; the size of a building comes from its storeys, setbacks, separations and the permeable surface required (our reading).

Smallest homes in townhouses: a secondary suite 32.52 m², a studio 37 m², one bedroom 56 m², two bedrooms 90 m², three 111 m², four 125 m²; each townhouse at least 5 m wide (Part 4-3.2.2).

A street or lane setback may drop to 0.0 m with a professional engineer's circulation plan that the City's General Manager Engineering approves (Part 4-1.3.1).

A swimming pool, covered or not, may sit in a required side or rear yard, never the front yard, and at least 3.0 m from every lot line (Part 4-1.4.2).

Along stretches of Kingsway, the Lougheed Highway, Hastings Street and Boundary Road, buildings must stand back a set distance from the road's centre line, 12.9 m to 30.2 m depending on the stretch (Part 4-1.3.3).

Parking under Part 7: 1.0 space for each apartment or townhouse plus 0.05 for visitors (1.25 for an apartment with a lock-off unit or a townhouse with a suite), purpose-built rental 0.5 plus 0.05 for visitors; none for homes in a Transit-Oriented Area or Frequent Transit Network Area (Part 7-1.3).

Accessory structures that aren't buildings (fences and retaining walls aside) at most 4.6 m high outside the required front and side yards (Part 4-2.1.2).

Every part of the lot not used for buildings, parking or loading, outdoor recreation or utility corridors is landscaped and kept up (Part 4-4.4.1).

Parking and loading areas and display yards: a landscaped strip at least 1.8 m wide along a street or a next-door A or R lot; parking and loading screened 1.8 m high where they abut an A or R lot or face one across a street or lane (0.8 to 1 m along a lane within 6.0 m of a driveway), display yards, industrial fueling and public utility installations where they abut one or face one across a lane; outdoor storage tanks and equipment screened 1.8 m high (Part 4-4.4.3).

Fences at most 1.07 m in a required front yard (an outdoor play area's enclosure 1.8 m) and 1.8 m behind it; an entrance arbor or gate at most 2.6 m high and 1.8 m wide; no barbed or razor wire (Part 4-4.5).

Retaining walls at most 1.2 m high (more only by a development variance permit, or rebuilding an existing wall in place where the site leaves no choice), stepped walls at least as far apart as the taller is high, the level ground between landscaped; a fence on a wall must look different from it (Part 4-4.5, 4-4.6).

At a corner, nothing over 1.07 m high but a principal building or a street canopy within the triangle 9.0 m along each street (6.0 m where a lane meets a lane or street), and nothing above grade within 3.0 m where two lanes meet (Part 4-1.5).

A telecommunication antenna may be attached to a building, at least 5.0 m above the ground, with at most 7.5 m² of antennae on a face and no more than 3 m above the top of that face; other antenna developments need a CD rezoning unless the E, I or P district allows them (Part 6-5.4.1).

No commercial vehicle, truck, bus, contractor's equipment, wrecked car, boat, RV or trailer parked or stored in the open, except in the rear yard: work vehicles while work on the place is under way and, registered to a resident, one truck or commercial vehicle up to 4,500 kg, one boat up to 6.0 m, one RV or trailer up to 6.0 m and at most two uninsured but operable cars. Residential parking spaces are for private non-commercial vehicles; an RV isn't a home (Part 2, Part 7-1.1.2, 7-1.3.3.2).

No accessory building or structure (fences and retaining walls aside) before the principal building or use it serves, unless built with it; an attached garage, carport or other accessory building counts as part of the principal building (Part 6-1.6). A building holding a home is never an accessory building (Part 2).

Temporary buildings only for construction, a business's move while its building is altered, a residential sales centre, film production or school classrooms, with the Chief Building Inspector's permit, and never used as a home; converting a building to another use needs the Chief Building Inspector's word that it's structurally suitable (Part 6-1.1, 6-1.2).

Beside a stream, ravine or ditch, a streamside protection and enhancement area is kept from the top of bank: 5 m to 30 m by the kind of stream and the width of its vegetation, 10 m in a ravine over 60 m wide or along a fish-bearing ditch, 5 m along a non-fish-bearing ditch, under the Streamside Protection and Enhancement Area development permit guidelines (Part 4-4.2). Whether a lot is near one we don't check here: ask the City.

On land in the Fraser River flood plain (the regional plan's flood plain map), buildings with rooms for living, business or storing goods floodwater would damage stand at least 60 m from the river's natural boundary, with the underside of the floor no lower than a line rising from 3.392 m (geodetic) at Boundary Road to 4.002 m at Fenwick Street (Part 4-4.1). Whether a lot is in it we don't check here: see the floodplain section and ask the City.

A home-based child care only in a ground-floor home, and only where the building's owner or manager (for a strata unit, the strata council) supports it to the City's satisfaction; no boarders, congregate or supportive housing, short-term rental or home occupation with clients on site in that home (Part 6-3.5).

Supportive housing, though listed, is to be part of a comprehensive development plan under the CD (Comprehensive Development) District (Part 6-3.6), so in practice it needs a CD rezoning (our reading).

A dormitory stands within 800 m of the land of the institution it serves (Part 6-5.2).

An emergency shelter only wholly inside a building, on land the City or a government body owns, leases or controls, run by one of them or a non-profit (Part 6-5.3).

At least half of the required permeable surface is planted (trees, shrubs, hedges, ground cover) in deep soil, not permeable paving; sod and the invasive plants on Metro Vancouver's list don't count. A roof with 0.6 m of growing medium or 0.9 m of structural soil counts (less soil counts in proportion) (Part 4-4.3).

Height in storeys leaves out rooftop access, mechanical penthouses and elevator overruns, an enclosed rooftop amenity storey covering at most 25% of the roof, and a first-storey mezzanine in a commercial or live-work unit in an R or C district that isn't a storey under the Building Code (Part 4-2.2.2).

A secondary suite: at most one in each primary home (in small-scale multi-unit housing, a rowhouse or a townhouse), wholly inside it, at least 32.52 m², never on a title of its own; no boarders, child care centre or home occupation with clients on site in a home that has one (a licensed home-based child care may run in the suite where it has no inside door to the main home) (Part 6-3.1, Part 4-3.2.2).

Boarding: at most 2 boarders or lodgers in a home, for 30 days or more at a time (Part 2).

Home occupations: no structural change to the home and no outside sign of the business; an artist studio for small-batch crafts is allowed, but no welding, manufacturing or light industry, and no noise, smoke, dust, odour or traffic beyond a home's; no outside storage of materials or products; nothing made elsewhere sold there; only household or hobby equipment (a resident physician or dentist excepted); residents only (one non-resident employee for a home-based child care); at most one customer and one customer vehicle at a time (Part 6-3.4).

A temporary use permit can't add a use to small-scale multi-unit housing, rowhouses, townhouses, apartments, suites, lock-off units or purpose-built rental housing, nor allow a liquor or cannabis store or cannabis production or processing (Part 6-1.3).

Uses the district doesn't list aren't allowed (Part 1, s. 4.1), besides transit, public utilities (at least 3 m from an A or R district lot), civic facilities and public parks and natural areas, allowed everywhere (Part 6-1.4).

Parts 4 (general regulations), 6 (use-specific regulations) and 7 (parking) of the bylaw also apply.

Short-term rental isn't allowed in a rental unit (Part 6-3.3), so in practice not here (our reading).

Site-specific exceptions listed in the bylaw by legal description can add or change uses for one property, and development permit areas, the ALR and building rules apply on top. Confirm with the City of Burnaby's planning department before you buy or build.

Source: Part 3, Section 1.2 of Burnaby Zoning Bylaw 2026, No. 14815 (summarised in our words, checked 2026-10-30); zone map: Open Government Licence – Burnaby.

Burnaby Zoning Bylaw 2026, No. 14815 applies in Burnaby.

Other residential districts R1 to R5, the rental sub-districts R2r to R5r, the neighbourhood commercial (C1) and general commercial (C2), employment (E1), industrial (I1), parks and natural areas (P1, P1a) and institutional (P2) districts, the heavy industrial sub-district (I1a) and the agriculture district (A1) zones in this bylaw

R1 Small-Scale Multi-Unit Housing, R2 Townhouse, R3 Low-Rise Apartment 1, R4 Low-Rise Apartment 2, R5 Mid-Rise Apartment 1, R3r Low-Rise Apartment 1 (rental), R4r Low-Rise Apartment 2 (rental), R5r Mid-Rise Apartment 1 (rental), C1 Neighbourhood Commercial, E1 Employment, I1 Industrial, P1 Parks, Open Spaces and Natural Areas, P1a Parks, Open Spaces and Natural Areas (natural areas), P2 Institutional, I1a Industrial (heavy industrial sub-district), A1 Agriculture, C2 General Commercial.