What the zone allows
- Homes allowed
- None
Exceptions (1)
- Multi-family homes on two named lots on Annesty Road
Listed in s. 15.1 of the bylaw.
- Main uses
- Government, education, recreation and health facilities, utilities, places of assembly, museum, community hall; festivals, auctions, trade shows and similar short events, accessory buildings
- Smallest lot for a subdivision
- 1,000 m²
- Lot coverage
- No maximum
- Height limit
- No maximum
- Setbacks
- Front 6 m, sides 1.5 m (4.5 m beside a street), rear 6 m (accessory buildings 1.5 m)
Site-specific (s. 15.1): multi-family homes are also allowed on two named lots on Annesty Road (Bylaw 224).
Parking (s. 3.10): elementary schools 2 spaces per classroom, secondary schools 5; assembly 1 per 5 seats; clinics 2 per examination room plus 3 for an emergency room and 3 per other clinic room.
No accessory building before the main building is built or permitted (s. 3.5(a)); each accessory building is at most 65 m² of floor area on lots under 4,000 m² (s. 3.5(d)) and keeps the main building's front and street-side setbacks, in the main building's character (s. 3.5(e)); a storage container used as one is at most 3 m tall unless it has a peaked roof (s. 3.5(c)).
At a street corner, nothing more than 0.8 m above the roads' grade within the triangle reaching 24 m along each road's centre line from where they meet (s. 3.11).
No building or structure within 30 m of the Barriere or North Thompson River, 15 m of any other watercourse or 7.5 m of the inside toe of a dike. Floors used for living, business or storing goods that floodwater would damage stand at the North Thompson or Barriere River's flood construction level (or 3 m above the Barriere River's natural boundary where none is set) and 1.5 m above any other watercourse; the floor rule leaves out a renovation of an existing home with no addition, an addition to a home of under 25% of its floor area, garages and carports, farm buildings other than homes and closed livestock barns, and industrial buildings flood-proofed to the engineered level or behind an approved dike (s. 3.4(b) to (d)). Fill used to reach the level keeps its slope out of those distances from the water and is protected from erosion, and no furnace or other fixed equipment sits below the level; the District may ask for a BC land surveyor's plan of the natural boundary, dike or floodplain (s. 3.4(e), (f)). An accessory building for storing marine equipment that floodwater wouldn't damage needs no setback from a lot line along a watercourse, subject to the riparian area rules and any development permit (s. 3.5(b)); as we read it, the distances from the water above still apply, as s. 3.4(b) holds notwithstanding the rest of the bylaw.
On ALR land the Agricultural Land Reserve rules come first: no subdivision or new non-farm use without the Commission's approval (s. 2.4).
Every zone also allows public uses (roads, parks, tourist information, water and sewer works, hydro substations, telephone exchanges, municipal halls, fire and ambulance stations, schools), trails and sports courts, conservation, flood and erosion control, landscaping, fences and walls, transit shelters, sheds and scaffolds while building is under way, a temporary sales office for new lots or units (30 m from any occupied home), special events the District licenses or approves, processing firewood for your own use and a home occupation (a home-based business in every zone but RM) (s. 3.13); banned everywhere are bulk hazardous storage not tied to a permitted use, commercial slaughtering and rendering, feedlots and stockyards, and biosolids brought in for resale (s. 3.14). Telecom towers are allowed in any zone on a lot of 2 ha or more, 150 m from a residential zone (s. 3.13(f)).
Minimum lot sizes apply to new lots; a smaller lot registered before the bylaw may use all the zone's uses if its sewage disposal meets the Public Health Act (s. 3.2). A lot in two zones follows each zone on its own part (s. 3.3). The front lot line is the boundary with a highway; on a corner lot the owner picks which line is the front and which the exterior side, and on a lot with a continuous curve the whole curve is the front. Setbacks also apply to lot lines along access routes in a bare land strata plan. Eaves, gutters, sills, chimneys and similar features may reach 60 cm into a setback, and uncovered patios, terraces, steps and stairs don't count (s. 1).
Height is measured from the average finished grade to the highest point, leaving out chimneys, antennas and rooftop equipment (s. 1).
Site-specific exceptions listed in the bylaw by legal description can add or change uses for one property, and development permit areas, the ALR and building rules apply on top. Confirm with the District of Barriere's office before you buy or build.
Source: District of Barriere Zoning Bylaw No. 111 (summarised in our words, checked 2026-10-29); zone map: Open Government Licence – Thompson-Nicola Regional District.
District of Barriere Zoning Bylaw No. 111 applies in Barriere.
P-2 in other BC bylaws: what P-2 allows in each of the 23 we've summarised.
Other zones in this bylaw
SH Small Holding, CR Country Residential, R Residential, RM Residential Multi-Family, MH Mobile Home Park, C1 Downtown Core Commercial, C1/R Downtown Core Commercial/Residential, C1/RM Downtown Core Commercial/Residential Multi-Family, C2 Yellowhead Corridor Commercial, C2/R Yellowhead Corridor Commercial/Residential, LIC/R Light Industrial Commercial/Residential, I Industrial, I/C2 Industrial/Yellowhead Corridor Commercial, P1 Recreational, OS Open Space, TR Transportation - Rail.